Growatt MID 25KTL3-X2 (Pro.E) vs GoodWe GW25K-SDT-CN-G41
VS
The verdict
9 differences, and they point both ways
The largest is max input current per tracker: 19.0 A more headroom. 9 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
9
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 18 parameters
What actually differs
Parameter
MID 25KTL3-X2 (Pro.E)
GW25K-SDT-CN-G41
Difference
Max input current per tracker
40.0 A
21.0 A
19.0 A more headroom
Weight
24.0 kg
19.0 kg
5.0 kg lighter
Max AC power
27.70 kW
27.50 kW
0.20 kW apart
Nominal AC voltage
400 V
380 V
20 V apart
Start voltage
200 V
160 V
40 V earlier start
MPP trackers
3
2
1 tracker more
MPPT voltage range
200-1000 V
140-1000 V
200-1000 V vs 140-1000 V
Weight per kW
1.0 kg/kW
0.8 kg/kW
0.2 kg/kW lighter
Dimensions
415x528x225 mm
413x530x211 mm
415x528x225 mm vs 413x530x211 mm
02
Full specification
Parameter
MID 25KTL3-X2 (Pro.E)
GW25K-SDT-CN-G41
Difference
AC output
Rated AC power
25.00 kW
25.00 kW
Same
Max AC power
27.70 kW
27.50 kW
0.20 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
380 V
20 V apart
Max AC current
42.0 A
41.7 A
Effectively the same
PV input
Max PV power
37.50 kW
-
Not published by GoodWe
DC/AC ratio
1.50
-
Not published by GoodWe
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
140-1000 V
200-1000 V vs 140-1000 V
Start voltage
200 V
160 V
-40 V for GW25K-SDT-CN-G41
MPP trackers
3
2
+1 trackers for MID 25KTL3-X2 (Pro.E)
Strings per tracker
-
2
Not published by Growatt
Max input current per tracker
40.0 A
21.0 A
+19.0 A for MID 25KTL3-X2 (Pro.E)
Efficiency
European efficiency
98.6 %
-
Not published by GoodWe
Max efficiency
98.8 %
98.7 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
24.0 kg
19.0 kg
-5.0 kg for GW25K-SDT-CN-G41
Weight per kW
1.0 kg/kW
0.8 kg/kW
-0.2 kg/kW for GW25K-SDT-CN-G41
Dimensions
415x528x225 mm
413x530x211 mm
415x528x225 mm vs 413x530x211 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
45 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by GoodWe
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by GoodWe
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MID 25KTL3-X2 (Pro.E) vs Growatt MID 25KTL3-X
6 differences, the largest is start voltage
Same type, similar size
Growatt
Growatt MID 25KTL3-X2 (Pro.E) vs Growatt MID 25KTL3-X1
5 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MID 25KTL3-X2 (Pro.E) vs GoodWe GW25K-MT
10 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.