Skip to main content
MID 25KTL3-X2 (Pro.E) vs GW25K-SDT-CN-G41 9 of 18 identical Swap Change inverters

Growatt MID 25KTL3-X2 (Pro.E) vs GoodWe GW25K-SDT-CN-G41

Growatt MID 25KTL3-X2 (Pro.E)
Growatt
MID 25KTL3-X2 (Pro.E)
25 kW 98.6 % euro Grid-tie
VS
GoodWe GW25K-SDT-CN-G41
GoodWe
GW25K-SDT-CN-G41
25 kW Grid-tie
The verdict

9 differences, and they point both ways

The largest is max input current per tracker: 19.0 A more headroom. 9 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
9 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 18 parameters
Parameter MID 25KTL3-X2 (Pro.E) GW25K-SDT-CN-G41 Difference
Max input current per tracker 40.0 A 21.0 A 19.0 A more headroom
Weight 24.0 kg 19.0 kg 5.0 kg lighter
Max AC power 27.70 kW 27.50 kW 0.20 kW apart
Nominal AC voltage 400 V 380 V 20 V apart
Start voltage 200 V 160 V 40 V earlier start
MPP trackers 3 2 1 tracker more
MPPT voltage range 200-1000 V 140-1000 V 200-1000 V vs 140-1000 V
Weight per kW 1.0 kg/kW 0.8 kg/kW 0.2 kg/kW lighter
Dimensions 415x528x225 mm 413x530x211 mm 415x528x225 mm vs 413x530x211 mm
02

Full specification

Parameter MID 25KTL3-X2 (Pro.E) GW25K-SDT-CN-G41 Difference
AC output
Rated AC power 25.00 kW 25.00 kW Same
Max AC power 27.70 kW 27.50 kW 0.20 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 380 V 20 V apart
Max AC current 42.0 A 41.7 A Effectively the same
PV input
Max PV power 37.50 kW - Not published by GoodWe
DC/AC ratio 1.50 - Not published by GoodWe
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 140-1000 V 200-1000 V vs 140-1000 V
Start voltage 200 V 160 V -40 V for GW25K-SDT-CN-G41
MPP trackers 3 2 +1 trackers for MID 25KTL3-X2 (Pro.E)
Strings per tracker - 2 Not published by Growatt
Max input current per tracker 40.0 A 21.0 A +19.0 A for MID 25KTL3-X2 (Pro.E)
Efficiency
European efficiency 98.6 % - Not published by GoodWe
Max efficiency 98.8 % 98.7 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 24.0 kg 19.0 kg -5.0 kg for GW25K-SDT-CN-G41
Weight per kW 1.0 kg/kW 0.8 kg/kW -0.2 kg/kW for GW25K-SDT-CN-G41
Dimensions 415x528x225 mm 413x530x211 mm 415x528x225 mm vs 413x530x211 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - 45 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by GoodWe
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by GoodWe
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MID 25KTL3-X2 (Pro.E) vs Growatt MID 25KTL3-X
6 differences, the largest is start voltage
Same type, similar size
Growatt
Growatt MID 25KTL3-X2 (Pro.E) vs Growatt MID 25KTL3-X1
5 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MID 25KTL3-X2 (Pro.E) vs GoodWe GW25K-MT
10 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.