Growatt MAX 136KTL3-X MV vs Sungrow SG136TX
VS
The verdict
MAX 136KTL3-X MV leads on the differences that matter
The largest is max input current per tracker: 6.0 A more headroom. 10 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
10
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 19 parameters
What actually differs
Parameter
MAX 136KTL3-X MV
SG136TX
Difference
Max input current per tracker
32.0 A
26.0 A
6.0 A more headroom
Max AC power
136.00 kW
150.00 kW
14.00 kW apart
MPP trackers
10
12
2 trackers more
Weight
84.0 kg
92.5 kg
8.5 kg lighter
Nominal AC voltage
480 V
540 V
60 V apart
Max AC current
179.9 A
160.4 A
19.5 A apart
Start voltage
195 V
250 V
55 V earlier start
MPPT voltage range
180-1000 V
200-1000 V
180-1000 V vs 200-1000 V
Dimensions
640x970x345 mm
660x1051x362 mm
640x970x345 mm vs 660x1051x362 mm
02
Full specification
Parameter
MAX 136KTL3-X MV
SG136TX
Difference
AC output
Rated AC power
136.00 kW
136.00 kW
Same
Max AC power
136.00 kW
150.00 kW
14.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
480 V
540 V
60 V apart
Max AC current
179.9 A
160.4 A
19.5 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
180-1000 V
200-1000 V
180-1000 V vs 200-1000 V
Start voltage
195 V
250 V
-55 V for MAX 136KTL3-X MV
MPP trackers
10
12
+2 trackers for SG136TX
Strings per tracker
2
2
Same
Max input current per tracker
32.0 A
26.0 A
+6.0 A for MAX 136KTL3-X MV
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
99.0 %
99.0 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
84.0 kg
92.5 kg
-8.5 kg for MAX 136KTL3-X MV
Weight per kW
0.6 kg/kW
0.7 kg/kW
Effectively the same
Dimensions
640x970x345 mm
660x1051x362 mm
640x970x345 mm vs 660x1051x362 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Sungrow
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Growatt MAX 136KTL3-X MV vs Solis-136K-EHV-5G
6 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MAX 136KTL3-X MV vs Growatt MAX 136KTL3-X2 MV
2 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Growatt MAX 136KTL3-X MV vs Ginlong Solis S5-GC125K-HV
6 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.