Skip to main content
GW80K-MT vs S6-GC3P80K07-LV-ND 8 of 20 identical Swap Change inverters

GoodWe GW80K-MT vs Ginlong Solis S6-GC3P80K07-LV-ND

GoodWe GW80K-MT
GoodWe
GW80K-MT
80 kW 98.3 % euro Grid-tie
VS
Ginlong Solis S6-GC3P80K07-LV-ND
Ginlong Solis
S6-GC3P80K07-LV-ND
80 kW 98.3 % euro Grid-tie
The verdict

S6-GC3P80K07-LV-ND leads on the differences that matter

The largest is max dc voltage: 300 V apart. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
8 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 20 parameters
Parameter GW80K-MT S6-GC3P80K07-LV-ND Difference
Max DC voltage 1100 V 800 V 300 V apart
MPP trackers 4 7 3 trackers more
Max input current per tracker 44.0 A 54.0 A 10.0 A more headroom
Weight 70.0 kg 105.0 kg 35.0 kg lighter
Weight per kW 0.9 kg/kW 1.3 kg/kW 0.4 kg/kW lighter
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 133.0 A 230.9 A 97.9 A apart
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 200-1000 V 160-800 V 200-1000 V vs 160-800 V
Start voltage 200 V 180 V 20 V earlier start
Strings per tracker 4 3 1 string apart
Dimensions 788x586x267 mm 869x1036x396 mm 788x586x267 mm vs 869x1036x396 mm
02

Full specification

Parameter GW80K-MT S6-GC3P80K07-LV-ND Difference
AC output
Rated AC power 80.00 kW 80.00 kW Same
Max AC power 88.00 kW 88.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 133.0 A 230.9 A 97.9 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1100 V 800 V 300 V apart
MPPT voltage range 200-1000 V 160-800 V 200-1000 V vs 160-800 V
Start voltage 200 V 180 V -20 V for S6-GC3P80K07-LV-ND
MPP trackers 4 7 +3 trackers for S6-GC3P80K07-LV-ND
Strings per tracker 4 3 1 string apart
Max input current per tracker 44.0 A 54.0 A +10.0 A for S6-GC3P80K07-LV-ND
Efficiency
European efficiency 98.3 % 98.3 % Same
Max efficiency 98.8 % 98.8 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 70.0 kg 105.0 kg -35.0 kg for GW80K-MT
Weight per kW 0.9 kg/kW 1.3 kg/kW -0.4 kg/kW for GW80K-MT
Dimensions 788x586x267 mm 869x1036x396 mm 788x586x267 mm vs 869x1036x396 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Ginlong Solis
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
GoodWe GW80K-MT vs Growatt MAX 80KTL3 LV
10 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
GoodWe GW80K-MT vs GoodWe GW80KBF-MT
3 differences, the largest is weight
Same type, similar size
GoodWe
GoodWe GW80K-MT vs GoodWe GW80KHV-MT
3 differences, the largest is weight
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.