Ginlong Solis S6-GC3P80K07-LV-ND vs GoodWe GW80K-MT
VS
The verdict
S6-GC3P80K07-LV-ND leads on the differences that matter
The largest is max dc voltage: 300 V apart. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
8
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 20 parameters
What actually differs
Parameter
S6-GC3P80K07-LV-ND
GW80K-MT
Difference
Max DC voltage
800 V
1100 V
300 V apart
MPP trackers
7
4
3 trackers more
Max input current per tracker
54.0 A
44.0 A
10.0 A more headroom
Weight
105.0 kg
70.0 kg
35.0 kg lighter
Weight per kW
1.3 kg/kW
0.9 kg/kW
0.4 kg/kW lighter
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
230.9 A
133.0 A
97.9 A apart
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
160-800 V
200-1000 V
160-800 V vs 200-1000 V
Start voltage
180 V
200 V
20 V earlier start
Strings per tracker
3
4
1 string apart
Dimensions
869x1036x396 mm
788x586x267 mm
869x1036x396 mm vs 788x586x267 mm
02
Full specification
Parameter
S6-GC3P80K07-LV-ND
GW80K-MT
Difference
AC output
Rated AC power
80.00 kW
80.00 kW
Same
Max AC power
88.00 kW
88.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
230.9 A
133.0 A
97.9 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
800 V
1100 V
300 V apart
MPPT voltage range
160-800 V
200-1000 V
160-800 V vs 200-1000 V
Start voltage
180 V
200 V
-20 V for S6-GC3P80K07-LV-ND
MPP trackers
7
4
+3 trackers for S6-GC3P80K07-LV-ND
Strings per tracker
3
4
1 string apart
Max input current per tracker
54.0 A
44.0 A
+10.0 A for S6-GC3P80K07-LV-ND
Efficiency
European efficiency
98.3 %
98.3 %
Same
Max efficiency
98.8 %
98.8 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
105.0 kg
70.0 kg
-35.0 kg for GW80K-MT
Weight per kW
1.3 kg/kW
0.9 kg/kW
-0.4 kg/kW for GW80K-MT
Dimensions
869x1036x396 mm
788x586x267 mm
869x1036x396 mm vs 788x586x267 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Ginlong Solis S6-GC3P80K07-LV-ND vs Growatt MAX 80KTL3 LV
14 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Ginlong Solis S6-GC3P80K07-LV-ND vs GoodWe GW80KBF-MT
13 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Ginlong Solis S6-GC3P80K07-LV-ND vs GoodWe GW80KHV-MT
13 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.