Skip to main content
S6-GC3P80K07-LV-ND vs GW80K-MT 8 of 20 identical Swap Change inverters

Ginlong Solis S6-GC3P80K07-LV-ND vs GoodWe GW80K-MT

Ginlong Solis S6-GC3P80K07-LV-ND
Ginlong Solis
S6-GC3P80K07-LV-ND
80 kW 98.3 % euro Grid-tie
VS
GoodWe GW80K-MT
GoodWe
GW80K-MT
80 kW 98.3 % euro Grid-tie
The verdict

S6-GC3P80K07-LV-ND leads on the differences that matter

The largest is max dc voltage: 300 V apart. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
8 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 20 parameters
Parameter S6-GC3P80K07-LV-ND GW80K-MT Difference
Max DC voltage 800 V 1100 V 300 V apart
MPP trackers 7 4 3 trackers more
Max input current per tracker 54.0 A 44.0 A 10.0 A more headroom
Weight 105.0 kg 70.0 kg 35.0 kg lighter
Weight per kW 1.3 kg/kW 0.9 kg/kW 0.4 kg/kW lighter
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 230.9 A 133.0 A 97.9 A apart
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 160-800 V 200-1000 V 160-800 V vs 200-1000 V
Start voltage 180 V 200 V 20 V earlier start
Strings per tracker 3 4 1 string apart
Dimensions 869x1036x396 mm 788x586x267 mm 869x1036x396 mm vs 788x586x267 mm
02

Full specification

Parameter S6-GC3P80K07-LV-ND GW80K-MT Difference
AC output
Rated AC power 80.00 kW 80.00 kW Same
Max AC power 88.00 kW 88.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 230.9 A 133.0 A 97.9 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 800 V 1100 V 300 V apart
MPPT voltage range 160-800 V 200-1000 V 160-800 V vs 200-1000 V
Start voltage 180 V 200 V -20 V for S6-GC3P80K07-LV-ND
MPP trackers 7 4 +3 trackers for S6-GC3P80K07-LV-ND
Strings per tracker 3 4 1 string apart
Max input current per tracker 54.0 A 44.0 A +10.0 A for S6-GC3P80K07-LV-ND
Efficiency
European efficiency 98.3 % 98.3 % Same
Max efficiency 98.8 % 98.8 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 105.0 kg 70.0 kg -35.0 kg for GW80K-MT
Weight per kW 1.3 kg/kW 0.9 kg/kW -0.4 kg/kW for GW80K-MT
Dimensions 869x1036x396 mm 788x586x267 mm 869x1036x396 mm vs 788x586x267 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Ginlong Solis
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Ginlong Solis S6-GC3P80K07-LV-ND vs Growatt MAX 80KTL3 LV
14 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Ginlong Solis S6-GC3P80K07-LV-ND vs GoodWe GW80KBF-MT
13 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Ginlong Solis S6-GC3P80K07-LV-ND vs GoodWe GW80KHV-MT
13 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.