Skip to main content
GW60KS-MT vs SUN2000-60KTL-M0 9 of 20 identical Swap Change inverters

GoodWe GW60KS-MT vs Huawei SUN2000-60KTL-M0

GoodWe GW60KS-MT
GoodWe
GW60KS-MT
60 kW 98.1 % euro Grid-tie
VS
Huawei SUN2000-60KTL-M0
Huawei
SUN2000-60KTL-M0
60 kW 98.7 % euro Grid-tie
The verdict

11 differences, and they point both ways

The largest is european efficiency: 0.6 pp more efficient. 9 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
9 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 20 parameters
Parameter GW60KS-MT SUN2000-60KTL-M0 Difference
European efficiency 98.1 % 98.7 % 0.6 pp more efficient
Max input current per tracker 30.0 A 22.0 A 8.0 A more headroom
Weight 55.0 kg 74.0 kg 19.0 kg lighter
Max efficiency 98.6 % 98.9 % 0.3 pp more efficient
Nominal AC voltage 400 V 480 V 80 V apart
Max AC current 96.0 A 79.4 A 16.6 A apart
Weight per kW 0.9 kg/kW 1.2 kg/kW 0.3 kg/kW lighter
MPPT voltage range 200-950 V 200-1000 V 200-950 V vs 200-1000 V
Start voltage 180 V 200 V 20 V earlier start
Dimensions 660x520x220 mm 555x1075x300 mm 660x520x220 mm vs 555x1075x300 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter GW60KS-MT SUN2000-60KTL-M0 Difference
AC output
Rated AC power 60.00 kW 60.00 kW Same
Max AC power 66.00 kW 66.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 480 V 80 V apart
Max AC current 96.0 A 79.4 A 16.6 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-950 V 200-1000 V 200-950 V vs 200-1000 V
Start voltage 180 V 200 V -20 V for GW60KS-MT
MPP trackers - 6 Not published by GoodWe
Strings per tracker 2 2 Same
Max input current per tracker 30.0 A 22.0 A +8.0 A for GW60KS-MT
Efficiency
European efficiency 98.1 % 98.7 % +0.6 pp for SUN2000-60KTL-M0
Max efficiency 98.6 % 98.9 % +0.3 pp for SUN2000-60KTL-M0
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 55.0 kg 74.0 kg -19.0 kg for GW60KS-MT
Weight per kW 0.9 kg/kW 1.2 kg/kW -0.3 kg/kW for GW60KS-MT
Dimensions 660x520x220 mm 555x1075x300 mm 660x520x220 mm vs 555x1075x300 mm
Ingress protection IP65 IP65 Same
Cooling forced-air natural forced-air vs natural
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Sungrow
GoodWe GW60KS-MT vs Sungrow SG60KTL-182
9 differences, the largest is european efficiency
Same type, similar size
GoodWe
GoodWe GW60KS-MT vs GoodWe GW60KN-MT
8 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
GoodWe GW60KS-MT vs Solis-60K-4G
9 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-60KTL-M0 vs Growatt MAX 60KTL3 LV
9 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.