SUN2000-60KTL-M0 vs MAX 60KTL3 LV 11 of 20 identical Swap Change inverters

Huawei SUN2000-60KTL-M0 vs Growatt MAX 60KTL3 LV

Huawei SUN2000-60KTL-M0
Huawei
SUN2000-60KTL-M0
60 kW 98.7 % euro Grid-tie
VS
Growatt MAX 60KTL3 LV
Growatt
MAX 60KTL3 LV
60 kW 98.4 % euro Grid-tie
The verdict

SUN2000-60KTL-M0 leads on the differences that matter

The largest is max input current per tracker: 4.0 A more headroom. 11 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
11 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 20 parameters
Parameter SUN2000-60KTL-M0 MAX 60KTL3 LV Difference
Max input current per tracker 22.0 A 26.0 A 4.0 A more headroom
Max AC power 66.00 kW 66.60 kW 0.60 kW apart
Weight 74.0 kg 82.0 kg 8.0 kg lighter
European efficiency 98.7 % 98.4 % 0.3 pp more efficient
Nominal AC voltage 480 V 400 V 80 V apart
Max AC current 79.4 A 96.6 A 17.2 A apart
Start voltage 200 V 250 V 50 V earlier start
Dimensions 555x1075x300 mm 600x860x300 mm 555x1075x300 mm vs 600x860x300 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter SUN2000-60KTL-M0 MAX 60KTL3 LV Difference
AC output
Rated AC power 60.00 kW 60.00 kW Same
Max AC power 66.00 kW 66.60 kW 0.60 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 480 V 400 V 80 V apart
Max AC current 79.4 A 96.6 A 17.2 A apart
PV input
Max PV power - 90.00 kW Not published by Huawei
DC/AC ratio - 1.50 Not published by Huawei
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 200-1000 V Same
Start voltage 200 V 250 V -50 V for SUN2000-60KTL-M0
MPP trackers 6 - Not published by Growatt
Strings per tracker 2 2 Same
Max input current per tracker 22.0 A 26.0 A +4.0 A for MAX 60KTL3 LV
Efficiency
European efficiency 98.7 % 98.4 % +0.3 pp for SUN2000-60KTL-M0
Max efficiency 98.9 % 98.8 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 74.0 kg 82.0 kg -8.0 kg for SUN2000-60KTL-M0
Weight per kW 1.2 kg/kW 1.4 kg/kW Effectively the same
Dimensions 555x1075x300 mm 600x860x300 mm 555x1075x300 mm vs 600x860x300 mm
Ingress protection IP65 IP65 Same
Cooling natural forced-air natural vs forced-air
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
Sungrow
Huawei SUN2000-60KTL-M0 vs Sungrow SG60KTL-182
12 differences, the largest is mpp trackers
Same type, similar size
GoodWe
Huawei SUN2000-60KTL-M0 vs GoodWe GW60KN-MT
9 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Huawei SUN2000-60KTL-M0 vs Solis-60K-4G
9 differences, the largest is max input current per tracker
04

Written summary