GoodWe GW60KN-MT vs Ginlong Solis S6-GC3P60K05-NV-ND
VS
The verdict
GW60KN-MT leads on the differences that matter
The largest is max input current per tracker: 4.0 A more headroom. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
8
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 20 parameters
What actually differs
Parameter
GW60KN-MT
S6-GC3P60K05-NV-ND
Difference
Max input current per tracker
44.0 A
40.0 A
4.0 A more headroom
European efficiency
98.5 %
98.1 %
0.4 pp more efficient
Max AC power
66.00 kW
60.00 kW
6.00 kW apart
Weight
64.0 kg
38.6 kg
25.4 kg lighter
Weight per kW
1.1 kg/kW
0.6 kg/kW
0.4 kg/kW lighter
Max AC current
96.0 A
91.2 A
4.8 A apart
Max efficiency
98.8 %
98.6 %
0.2 pp more efficient
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
200-1000 V
180-1000 V
200-1000 V vs 180-1000 V
Start voltage
200 V
180 V
20 V earlier start
Strings per tracker
4
2
2 strings apart
Dimensions
788x586x267 mm
672x515x288 mm
788x586x267 mm vs 672x515x288 mm
02
Full specification
Parameter
GW60KN-MT
S6-GC3P60K05-NV-ND
Difference
AC output
Rated AC power
60.00 kW
60.00 kW
Same
Max AC power
66.00 kW
60.00 kW
6.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
96.0 A
91.2 A
4.8 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
180-1000 V
200-1000 V vs 180-1000 V
Start voltage
200 V
180 V
-20 V for S6-GC3P60K05-NV-ND
MPP trackers
4
-
Not published by Ginlong Solis
Strings per tracker
4
2
2 strings apart
Max input current per tracker
44.0 A
40.0 A
+4.0 A for GW60KN-MT
Efficiency
European efficiency
98.5 %
98.1 %
+0.4 pp for GW60KN-MT
Max efficiency
98.8 %
98.6 %
+0.2 pp for GW60KN-MT
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
64.0 kg
38.6 kg
-25.4 kg for S6-GC3P60K05-NV-ND
Weight per kW
1.1 kg/kW
0.6 kg/kW
-0.4 kg/kW for S6-GC3P60K05-NV-ND
Dimensions
788x586x267 mm
672x515x288 mm
788x586x267 mm vs 672x515x288 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
-
60 dB
Not published by GoodWe
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by GoodWe
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
GoodWe GW60KN-MT vs Huawei SUN2000-60KTL-M0
9 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
GoodWe GW60KN-MT vs Sungrow SG60KTL-182
9 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
GoodWe GW60KN-MT vs Solis-60K-4G
6 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.