GoodWe GW60KN-MT
GoodWe
GW60KN-MT
60 kW 98.5 % euro Grid-tie
VS
Ginlong Solis S6-GC3P60K05-NV-ND
Ginlong Solis
S6-GC3P60K05-NV-ND
60 kW 98.1 % euro Grid-tie
The verdict

GW60KN-MT leads on the differences that matter

The largest is max input current per tracker: 4.0 A more headroom. 8 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
8 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 20 parameters
Parameter GW60KN-MT S6-GC3P60K05-NV-ND Difference
Max input current per tracker 44.0 A 40.0 A 4.0 A more headroom
European efficiency 98.5 % 98.1 % 0.4 pp more efficient
Max AC power 66.00 kW 60.00 kW 6.00 kW apart
Weight 64.0 kg 38.6 kg 25.4 kg lighter
Weight per kW 1.1 kg/kW 0.6 kg/kW 0.4 kg/kW lighter
Max AC current 96.0 A 91.2 A 4.8 A apart
Max efficiency 98.8 % 98.6 % 0.2 pp more efficient
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Start voltage 200 V 180 V 20 V earlier start
Strings per tracker 4 2 2 strings apart
Dimensions 788x586x267 mm 672x515x288 mm 788x586x267 mm vs 672x515x288 mm
02

Full specification

Parameter GW60KN-MT S6-GC3P60K05-NV-ND Difference
AC output
Rated AC power 60.00 kW 60.00 kW Same
Max AC power 66.00 kW 60.00 kW 6.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 96.0 A 91.2 A 4.8 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Start voltage 200 V 180 V -20 V for S6-GC3P60K05-NV-ND
MPP trackers 4 - Not published by Ginlong Solis
Strings per tracker 4 2 2 strings apart
Max input current per tracker 44.0 A 40.0 A +4.0 A for GW60KN-MT
Efficiency
European efficiency 98.5 % 98.1 % +0.4 pp for GW60KN-MT
Max efficiency 98.8 % 98.6 % +0.2 pp for GW60KN-MT
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 64.0 kg 38.6 kg -25.4 kg for S6-GC3P60K05-NV-ND
Weight per kW 1.1 kg/kW 0.6 kg/kW -0.4 kg/kW for S6-GC3P60K05-NV-ND
Dimensions 788x586x267 mm 672x515x288 mm 788x586x267 mm vs 672x515x288 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise - 60 dB Not published by GoodWe
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by GoodWe
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
GoodWe GW60KN-MT vs Huawei SUN2000-60KTL-M0
9 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
GoodWe GW60KN-MT vs Sungrow SG60KTL-182
9 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
GoodWe GW60KN-MT vs Solis-60K-4G
6 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.