Skip to main content
GW50KS-MT vs MAX 50KTL3 LV 10 of 20 identical Swap Change inverters

GoodWe GW50KS-MT vs Growatt MAX 50KTL3 LV

GoodWe GW50KS-MT
GoodWe
GW50KS-MT
50 kW 98.1 % euro Grid-tie
VS
Growatt MAX 50KTL3 LV
Growatt
MAX 50KTL3 LV
50 kW 98.4 % euro Grid-tie
The verdict

GW50KS-MT leads on the differences that matter

The largest is max input current per tracker: 4.0 A more headroom. 10 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
10 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 20 parameters
Parameter GW50KS-MT MAX 50KTL3 LV Difference
Max input current per tracker 30.0 A 26.0 A 4.0 A more headroom
Max AC power 55.00 kW 55.50 kW 0.50 kW apart
Weight 55.0 kg 82.0 kg 27.0 kg lighter
European efficiency 98.1 % 98.4 % 0.3 pp more efficient
Weight per kW 1.1 kg/kW 1.6 kg/kW 0.5 kg/kW lighter
Start voltage 180 V 250 V 70 V earlier start
Max efficiency 98.6 % 98.8 % 0.2 pp more efficient
MPPT voltage range 200-950 V 200-1000 V 200-950 V vs 200-1000 V
Max AC current 80.0 A 80.5 A 0.5 A apart
Dimensions 660x520x220 mm 600x860x300 mm 660x520x220 mm vs 600x860x300 mm
02

Full specification

Parameter GW50KS-MT MAX 50KTL3 LV Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 55.00 kW 55.50 kW 0.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 80.0 A 80.5 A 0.5 A apart
PV input
Max PV power - 75.00 kW Not published by GoodWe
DC/AC ratio - 1.50 Not published by GoodWe
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-950 V 200-1000 V 200-950 V vs 200-1000 V
Start voltage 180 V 250 V -70 V for GW50KS-MT
MPP trackers - - Neither datasheet publishes this
Strings per tracker 2 2 Same
Max input current per tracker 30.0 A 26.0 A +4.0 A for GW50KS-MT
Efficiency
European efficiency 98.1 % 98.4 % +0.3 pp for MAX 50KTL3 LV
Max efficiency 98.6 % 98.8 % +0.2 pp for MAX 50KTL3 LV
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 55.0 kg 82.0 kg -27.0 kg for GW50KS-MT
Weight per kW 1.1 kg/kW 1.6 kg/kW -0.5 kg/kW for GW50KS-MT
Dimensions 660x520x220 mm 600x860x300 mm 660x520x220 mm vs 600x860x300 mm
Ingress protection IP65 IP65 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by GoodWe
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
GoodWe GW50KS-MT vs Huawei SUN2000-50KTL-JPM0
11 differences, the largest is european efficiency
Same type, similar size
Huawei
GoodWe GW50KS-MT vs Huawei SUN2000-50KTL-M0
9 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
GoodWe GW50KS-MT vs Solis-50K-HV
7 differences, the largest is european efficiency
Same type, similar size
Sungrow
Growatt MAX 50KTL3 LV vs Sungrow SG50CX
6 differences, the largest is max ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.