GoodWe GW50KS-MT vs Growatt MAX 50KTL3 LV
VS
The verdict
GW50KS-MT leads on the differences that matter
The largest is max input current per tracker: 4.0 A more headroom. 10 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
10
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 20 parameters
What actually differs
Parameter
GW50KS-MT
MAX 50KTL3 LV
Difference
Max input current per tracker
30.0 A
26.0 A
4.0 A more headroom
Max AC power
55.00 kW
55.50 kW
0.50 kW apart
Weight
55.0 kg
82.0 kg
27.0 kg lighter
European efficiency
98.1 %
98.4 %
0.3 pp more efficient
Weight per kW
1.1 kg/kW
1.6 kg/kW
0.5 kg/kW lighter
Start voltage
180 V
250 V
70 V earlier start
Max efficiency
98.6 %
98.8 %
0.2 pp more efficient
MPPT voltage range
200-950 V
200-1000 V
200-950 V vs 200-1000 V
Max AC current
80.0 A
80.5 A
0.5 A apart
Dimensions
660x520x220 mm
600x860x300 mm
660x520x220 mm vs 600x860x300 mm
02
Full specification
Parameter
GW50KS-MT
MAX 50KTL3 LV
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
55.00 kW
55.50 kW
0.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
80.0 A
80.5 A
0.5 A apart
PV input
Max PV power
-
75.00 kW
Not published by GoodWe
DC/AC ratio
-
1.50
Not published by GoodWe
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-950 V
200-1000 V
200-950 V vs 200-1000 V
Start voltage
180 V
250 V
-70 V for GW50KS-MT
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
30.0 A
26.0 A
+4.0 A for GW50KS-MT
Efficiency
European efficiency
98.1 %
98.4 %
+0.3 pp for MAX 50KTL3 LV
Max efficiency
98.6 %
98.8 %
+0.2 pp for MAX 50KTL3 LV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
55.0 kg
82.0 kg
-27.0 kg for GW50KS-MT
Weight per kW
1.1 kg/kW
1.6 kg/kW
-0.5 kg/kW for GW50KS-MT
Dimensions
660x520x220 mm
600x860x300 mm
660x520x220 mm vs 600x860x300 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by GoodWe
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
GoodWe GW50KS-MT vs Huawei SUN2000-50KTL-JPM0
11 differences, the largest is european efficiency
Same type, similar size
Huawei
GoodWe GW50KS-MT vs Huawei SUN2000-50KTL-M0
9 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
GoodWe GW50KS-MT vs Solis-50K-HV
7 differences, the largest is european efficiency
Same type, similar size
Sungrow
Growatt MAX 50KTL3 LV vs Sungrow SG50CX
6 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.