Skip to main content
GW4600-SS vs MIN 4600TL-X2 (Pro) 6 of 19 identical Swap Change inverters

GoodWe GW4600-SS vs Growatt MIN 4600TL-X2 (Pro)

GoodWe
GW4600-SS
4.6 kW 97.4 % euro Grid-tie
VS
Growatt MIN 4600TL-X2 (Pro)
Growatt
MIN 4600TL-X2 (Pro)
4.6 kW 97.5 % euro Grid-tie
The verdict

MIN 4600TL-X2 (Pro) leads on the differences that matter

The largest is max dc voltage: 50 V apart. 6 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 19 parameters
Parameter GW4600-SS MIN 4600TL-X2 (Pro) Difference
Max DC voltage 500 V 550 V 50 V apart
Max efficiency 97.8 % 98.4 % 0.6 pp more efficient
Max AC power 5.10 kW 4.60 kW 0.50 kW apart
Max PV power 5.40 kW 6.90 kW 1.50 kW apart
DC/AC ratio 1.17 1.50 0.33 more oversizing headroom
Weight 18.0 kg 10.8 kg 7.2 kg lighter
Weight per kW 3.9 kg/kW 2.3 kg/kW 1.6 kg/kW lighter
Max AC current 23.0 A 20.9 A 2.1 A apart
Start voltage 125 V 50 V 75 V earlier start
MPP trackers 1 2 1 tracker more
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 125-450 V 40-550 V 125-450 V vs 40-550 V
Dimensions 390x397x180 mm 350x375x158 mm 390x397x180 mm vs 350x375x158 mm
02

Full specification

Parameter GW4600-SS MIN 4600TL-X2 (Pro) Difference
AC output
Rated AC power 4.60 kW 4.60 kW Same
Max AC power 5.10 kW 4.60 kW 0.50 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 23.0 A 20.9 A 2.1 A apart
PV input
Max PV power 5.40 kW 6.90 kW 1.50 kW apart
DC/AC ratio 1.17 1.50 +0.33 for MIN 4600TL-X2 (Pro)
Max DC voltage 500 V 550 V 50 V apart
MPPT voltage range 125-450 V 40-550 V 125-450 V vs 40-550 V
Start voltage 125 V 50 V -75 V for MIN 4600TL-X2 (Pro)
MPP trackers 1 2 +1 trackers for MIN 4600TL-X2 (Pro)
Strings per tracker - 1 Not published by GoodWe
Max input current per tracker - 18.0 A Not published by GoodWe
Efficiency
European efficiency 97.4 % 97.5 % Effectively the same
Max efficiency 97.8 % 98.4 % +0.6 pp for MIN 4600TL-X2 (Pro)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 18.0 kg 10.8 kg -7.2 kg for MIN 4600TL-X2 (Pro)
Weight per kW 3.9 kg/kW 2.3 kg/kW -1.6 kg/kW for MIN 4600TL-X2 (Pro)
Dimensions 390x397x180 mm 350x375x158 mm 390x397x180 mm vs 350x375x158 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise 25 dB - Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by GoodWe
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty 5 yrs - Not published by Growatt
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
GoodWe GW4600-SS vs Growatt MIN 4600TL-X
13 differences, the largest is max dc voltage
Same type, similar size
Fronius International
GoodWe GW4600-SS vs Fronius Primo 5.0-1 AUS
15 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
GoodWe GW4600-SS vs Ginlong Solis S6-GR1P4.6K
14 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.