GoodWe GW4600-SS vs Growatt MIN 4600TL-X
VS
The verdict
MIN 4600TL-X leads on the differences that matter
The largest is max dc voltage: 50 V apart. 8 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
8
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 21 parameters
What actually differs
Parameter
GW4600-SS
MIN 4600TL-X
Difference
Max DC voltage
500 V
550 V
50 V apart
Max efficiency
97.8 %
98.4 %
0.6 pp more efficient
Max PV power
5.40 kW
6.44 kW
1.04 kW apart
DC/AC ratio
1.17
1.40
0.23 more oversizing headroom
Weight
18.0 kg
10.8 kg
7.2 kg lighter
Weight per kW
3.9 kg/kW
2.3 kg/kW
1.6 kg/kW lighter
European efficiency
97.4 %
97.1 %
0.3 pp more efficient
MPP trackers
1
2
1 tracker more
Start voltage
125 V
100 V
25 V earlier start
Nominal AC voltage
230 V
220 V
10 V apart
Max AC current
23.0 A
22.0 A
1.0 A apart
MPPT voltage range
125-450 V
80-550 V
125-450 V vs 80-550 V
Dimensions
390x397x180 mm
350x375x158 mm
390x397x180 mm vs 350x375x158 mm
02
Full specification
Parameter
GW4600-SS
MIN 4600TL-X
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
5.10 kW
5.06 kW
Effectively the same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
220 V
10 V apart
Max AC current
23.0 A
22.0 A
1.0 A apart
PV input
Max PV power
5.40 kW
6.44 kW
1.04 kW apart
DC/AC ratio
1.17
1.40
+0.23 for MIN 4600TL-X
Max DC voltage
500 V
550 V
50 V apart
MPPT voltage range
125-450 V
80-550 V
125-450 V vs 80-550 V
Start voltage
125 V
100 V
-25 V for MIN 4600TL-X
MPP trackers
1
2
+1 trackers for MIN 4600TL-X
Strings per tracker
-
1
Not published by GoodWe
Max input current per tracker
-
12.5 A
Not published by GoodWe
Efficiency
European efficiency
97.4 %
97.1 %
+0.3 pp for GW4600-SS
Max efficiency
97.8 %
98.4 %
+0.6 pp for MIN 4600TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
18.0 kg
10.8 kg
-7.2 kg for MIN 4600TL-X
Weight per kW
3.9 kg/kW
2.3 kg/kW
-1.6 kg/kW for MIN 4600TL-X
Dimensions
390x397x180 mm
350x375x158 mm
390x397x180 mm vs 350x375x158 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
25 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by GoodWe
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
GoodWe GW4600-SS vs Growatt MIN 4600TL-X2 (Pro)
13 differences, the largest is max dc voltage
Same type, similar size
Fronius International
GoodWe GW4600-SS vs Fronius Primo 5.0-1 AUS
15 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
GoodWe GW4600-SS vs Ginlong Solis S6-GR1P4.6K
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.