GW40K-ET-10 leads on the differences that matter
The largest is max input current per tracker: 2.0 A more headroom. 9 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
9
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 24 parameters
What actually differs
Parameter
GW40K-ET-10
S6-EH3P40K-H
Difference
Max input current per tracker
42.0 A
40.0 A
2.0 A more headroom
European efficiency
97.8 %
97.4 %
0.4 pp more efficient
Max AC power
44.00 kW
40.00 kW
4.00 kW apart
Max PV power
60.00 kW
80.00 kW
20.00 kW apart
DC/AC ratio
1.50
2.00
0.50 more oversizing headroom
Max charge current
100 A
140 A
40 A faster charging
Weight
62.0 kg
73.0 kg
11.0 kg lighter
Max efficiency
98.1 %
97.8 %
0.3 pp more efficient
Nominal AC voltage
380 V
400 V
20 V apart
Max AC current
66.7 A
60.8 A
5.9 A apart
Weight per kW
1.6 kg/kW
1.8 kg/kW
0.3 kg/kW lighter
MPPT voltage range
165-850 V
150-850 V
165-850 V vs 150-850 V
Start voltage
160 V
180 V
20 V earlier start
Battery voltage
200-800 V
150-800 V
200-800 V vs 150-800 V
Dimensions
660x520x260 mm
880x530x290 mm
660x520x260 mm vs 880x530x290 mm
02
Full specification
Parameter
GW40K-ET-10
S6-EH3P40K-H
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.00 kW
40.00 kW
4.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
380 V
400 V
20 V apart
Max AC current
66.7 A
60.8 A
5.9 A apart
PV input
Max PV power
60.00 kW
80.00 kW
20.00 kW apart
DC/AC ratio
1.50
2.00
+0.50 for S6-EH3P40K-H
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
165-850 V
150-850 V
165-850 V vs 150-850 V
Start voltage
160 V
180 V
-20 V for GW40K-ET-10
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
42.0 A
40.0 A
+2.0 A for GW40K-ET-10
Efficiency
European efficiency
97.8 %
97.4 %
+0.4 pp for GW40K-ET-10
Max efficiency
98.1 %
97.8 %
+0.3 pp for GW40K-ET-10
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
200-800 V
150-800 V
200-800 V vs 150-800 V
Max charge current
100 A
140 A
+40 A for S6-EH3P40K-H
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
62.0 kg
73.0 kg
-11.0 kg for GW40K-ET-10
Weight per kW
1.6 kg/kW
1.8 kg/kW
-0.3 kg/kW for GW40K-ET-10
Dimensions
660x520x260 mm
880x530x290 mm
660x520x260 mm vs 880x530x290 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Ginlong Solis
Ethernet
-
Yes
Not published by GoodWe
Arc fault protection
Yes
-
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
GoodWe GW40K-ET-10 vs Growatt MID 40K-HU
13 differences, the largest is european efficiency
Same type, similar size
Deye
GoodWe GW40K-ET-10 vs Deye SUN-40K-SG01HP3-EU-BM4
13 differences, the largest is european efficiency
Same type, similar size
Growatt
GoodWe GW40K-ET-10 vs Growatt WT 40K-H-US L2 / WT 40K-HU-US L2
13 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.