Skip to main content
GW10K-ET-20 (ET G2) vs SUN2000-10KTL-M1 10 of 26 identical Swap Change inverters

GoodWe GW10K-ET-20 (ET G2) vs Huawei SUN2000-10KTL-M1

GoodWe GW10K-ET-20 (ET G2)
GoodWe
GW10K-ET-20 (ET G2)
10 kW Hybrid
VS
Huawei SUN2000-10KTL-M1
Huawei
SUN2000-10KTL-M1
10 kW 98.1 % euro Hybrid
The verdict

16 differences, and they point both ways

The largest is max dc voltage: 100 V apart. 10 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
10 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 26 parameters
Parameter GW10K-ET-20 (ET G2) SUN2000-10KTL-M1 Difference
Max DC voltage 1000 V 1100 V 100 V apart
Max input current per tracker 16.0 A 11.0 A 5.0 A more headroom
Max AC power 10.00 kW 11.00 kW 1.00 kW apart
Max PV power 16.00 kW 15.00 kW 1.00 kW apart
Max charge current 40 A 16 A 24 A faster charging
Weight 25.0 kg 17.0 kg 8.0 kg lighter
Weight per kW 2.5 kg/kW 1.7 kg/kW 0.8 kg/kW lighter
Max efficiency 98.2 % 98.6 % 0.4 pp more efficient
DC/AC ratio 1.60 1.50 0.10 more oversizing headroom
Max AC current 26.1 A 16.9 A 9.2 A apart
Start voltage 150 V 200 V 50 V earlier start
MPP trackers 3 2 1 tracker more
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 120-850 V 140-980 V 120-850 V vs 140-980 V
Battery voltage 150-720 V 600 V ~ 980 V 150-720 V vs 600 V ~ 980 V
Dimensions 460x496x221 mm 525x470x146 mm 460x496x221 mm vs 525x470x146 mm
02

Full specification

Parameter GW10K-ET-20 (ET G2) SUN2000-10KTL-M1 Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 10.00 kW 11.00 kW 1.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 26.1 A 16.9 A 9.2 A apart
PV input
Max PV power 16.00 kW 15.00 kW 1.00 kW apart
DC/AC ratio 1.60 1.50 +0.10 for GW10K-ET-20 (ET G2)
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 120-850 V 140-980 V 120-850 V vs 140-980 V
Start voltage 150 V 200 V -50 V for GW10K-ET-20 (ET G2)
MPP trackers 3 2 +1 trackers for GW10K-ET-20 (ET G2)
Strings per tracker 1 1 Same
Max input current per tracker 16.0 A 11.0 A +5.0 A for GW10K-ET-20 (ET G2)
Efficiency
European efficiency - 98.1 % Not published by GoodWe
Max efficiency 98.2 % 98.6 % +0.4 pp for SUN2000-10KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 150-720 V 600 V ~ 980 V 150-720 V vs 600 V ~ 980 V
Max charge current 40 A 16 A +24 A for GW10K-ET-20 (ET G2)
Backup power - 3.3 kW Not published by GoodWe
Physical
Weight 25.0 kg 17.0 kg -8.0 kg for SUN2000-10KTL-M1
Weight per kW 2.5 kg/kW 1.7 kg/kW -0.8 kg/kW for SUN2000-10KTL-M1
Dimensions 460x496x221 mm 525x470x146 mm 460x496x221 mm vs 525x470x146 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by GoodWe
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
GoodWe GW10K-ET-20 (ET G2) vs SolarEdge SE10000H
11 differences, the largest is max dc voltage
Same type, similar size
Growatt
GoodWe GW10K-ET-20 (ET G2) vs Growatt MOD 10KTL3-XH
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
GoodWe GW10K-ET-20 (ET G2) vs Growatt MOD 10KTL3-HU
12 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Huawei SUN2000-10KTL-M1 vs Huawei SUN2000-10KTL-M1 (High current version)
2 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.