Skip to main content
Solis-60K-4G vs SOFAR 60KTLX-G4-LV 7 of 21 identical Swap Change inverters

Solis-60K-4G vs SOFAR 60KTLX-G4-LV

Solis-60K-4G
Ginlong Solis
Solis-60K-4G
60 kW 98.5 % euro Grid-tie
VS
SOFAR 60KTLX-G4-LV
Sofar Solar
SOFAR 60KTLX-G4-LV
60 kW 98.0 % euro Grid-tie
The verdict

Solis-60K-4G leads on the differences that matter

The largest is european efficiency: 0.5 pp more efficient. 7 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
7 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 21 parameters
Parameter Solis-60K-4G SOFAR 60KTLX-G4-LV Difference
European efficiency 98.5 % 98.0 % 0.5 pp more efficient
Max DC voltage 1100 V 900 V 200 V apart
Max input current per tracker 28.5 A 40.0 A 11.5 A more headroom
Max PV power 72.00 kW 90.00 kW 18.00 kW apart
DC/AC ratio 1.20 1.50 0.30 more oversizing headroom
Weight 63.0 kg 75.0 kg 12.0 kg lighter
Max efficiency 99.0 % 98.5 % 0.5 pp more efficient
Nominal AC voltage 400 V 220 V 180 V apart
Max AC current 100.0 A 173.3 A 73.3 A apart
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 200-1000 V 180-800 V 200-1000 V vs 180-800 V
Weight per kW 1.1 kg/kW 1.2 kg/kW 0.2 kg/kW lighter
Strings per tracker 3 2 1 string apart
Dimensions 700x630x357 mm 695x970x325 mm 700x630x357 mm vs 695x970x325 mm
02

Full specification

Parameter Solis-60K-4G SOFAR 60KTLX-G4-LV Difference
AC output
Rated AC power 60.00 kW 60.00 kW Same
Max AC power 66.00 kW 66.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 220 V 180 V apart
Max AC current 100.0 A 173.3 A 73.3 A apart
PV input
Max PV power 72.00 kW 90.00 kW 18.00 kW apart
DC/AC ratio 1.20 1.50 +0.30 for SOFAR 60KTLX-G4-LV
Max DC voltage 1100 V 900 V 200 V apart
MPPT voltage range 200-1000 V 180-800 V 200-1000 V vs 180-800 V
Start voltage 200 V 200 V Same
MPP trackers 4 - Not published by Sofar Solar
Strings per tracker 3 2 1 string apart
Max input current per tracker 28.5 A 40.0 A +11.5 A for SOFAR 60KTLX-G4-LV
Efficiency
European efficiency 98.5 % 98.0 % +0.5 pp for Solis-60K-4G
Max efficiency 99.0 % 98.5 % +0.5 pp for Solis-60K-4G
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 63.0 kg 75.0 kg -12.0 kg for Solis-60K-4G
Weight per kW 1.1 kg/kW 1.2 kg/kW -0.2 kg/kW for Solis-60K-4G
Dimensions 700x630x357 mm 695x970x325 mm 700x630x357 mm vs 695x970x325 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Ginlong Solis
Integrated DC switch - Yes Not published by Ginlong Solis
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Solis-60K-4G vs Huawei SUN2000-60KTL-M0
9 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Solis-60K-4G vs Sungrow SG60KTL-182
10 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Solis-60K-4G vs GoodWe GW60KN-MT
6 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.