Solis-60K-4G vs SG60KTL-182 9 of 19 identical Swap Change inverters

Solis-60K-4G vs Sungrow SG60KTL-182

Solis-60K-4G
Ginlong Solis
Solis-60K-4G
60 kW 98.5 % euro Grid-tie
VS
Sungrow
SG60KTL-182
60 kW 98.7 % euro Grid-tie
The verdict

SG60KTL-182 leads on the differences that matter

The largest is max dc voltage: 100 V apart. 9 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 10 differences
How alike are they
9 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

10 of 19 parameters
Parameter Solis-60K-4G SG60KTL-182 Difference
Max DC voltage 1100 V 1000 V 100 V apart
MPP trackers 4 1 3 trackers more
Max input current per tracker 28.5 A 120.0 A 91.5 A more headroom
Weight 63.0 kg 60.0 kg 3.0 kg lighter
European efficiency 98.5 % 98.7 % 0.2 pp more efficient
Max AC current 100.0 A 96.0 A 4.0 A apart
Start voltage 200 V 620 V 420 V earlier start
Strings per tracker 3 14 11 strings apart
MPPT voltage range 200-1000 V 570-950 V 200-1000 V vs 570-950 V
Dimensions 700x630x357 mm 959x634x267 mm 700x630x357 mm vs 959x634x267 mm
02

Full specification

Parameter Solis-60K-4G SG60KTL-182 Difference
AC output
Rated AC power 60.00 kW 60.00 kW Same
Max AC power 66.00 kW 66.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 100.0 A 96.0 A 4.0 A apart
PV input
Max PV power 72.00 kW - Not published by Sungrow
DC/AC ratio 1.20 - Not published by Sungrow
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 200-1000 V 570-950 V 200-1000 V vs 570-950 V
Start voltage 200 V 620 V -420 V for Solis-60K-4G
MPP trackers 4 1 +3 trackers for Solis-60K-4G
Strings per tracker 3 14 11 strings apart
Max input current per tracker 28.5 A 120.0 A +91.5 A for SG60KTL-182
Efficiency
European efficiency 98.5 % 98.7 % +0.2 pp for SG60KTL-182
Max efficiency 99.0 % 98.9 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 63.0 kg 60.0 kg -3.0 kg for SG60KTL-182
Weight per kW 1.1 kg/kW 1.0 kg/kW Effectively the same
Dimensions 700x630x357 mm 959x634x267 mm 700x630x357 mm vs 959x634x267 mm
Ingress protection IP65 IP65 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Sungrow
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - Yes Not published by Ginlong Solis
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Solis-60K-4G vs Huawei SUN2000-60KTL-M0
9 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Solis-60K-4G vs GoodWe GW60KN-MT
6 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Solis-60K-4G vs Growatt MAX 60KTL3 LV
11 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.