Solis-60K-4G vs S6-GC60K-LV 7 of 19 identical Swap Change inverters

Solis-60K-4G vs Ginlong Solis S6-GC60K-LV

Solis-60K-4G
Ginlong Solis
Solis-60K-4G
60 kW 98.5 % euro Grid-tie
VS
Ginlong Solis S6-GC60K-LV
Ginlong Solis
S6-GC60K-LV
60 kW 98.3 % euro Grid-tie
The verdict

Solis-60K-4G leads on the differences that matter

The largest is max input current per tracker: 13.5 A more headroom. 7 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
7 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 19 parameters
Parameter Solis-60K-4G S6-GC60K-LV Difference
Max input current per tracker 28.5 A 42.0 A 13.5 A more headroom
Weight 63.0 kg 93.0 kg 30.0 kg lighter
European efficiency 98.5 % 98.3 % 0.2 pp more efficient
Weight per kW 1.1 kg/kW 1.6 kg/kW 0.5 kg/kW lighter
Max efficiency 99.0 % 98.7 % 0.3 pp more efficient
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 100.0 A 173.2 A 73.2 A apart
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 200-1000 V 160-1000 V 200-1000 V vs 160-1000 V
Start voltage 200 V 180 V 20 V earlier start
Strings per tracker 3 2 1 string apart
Dimensions 700x630x357 mm 567x1014x345 mm 700x630x357 mm vs 567x1014x345 mm
02

Full specification

Parameter Solis-60K-4G S6-GC60K-LV Difference
AC output
Rated AC power 60.00 kW 60.00 kW Same
Max AC power 66.00 kW 66.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 100.0 A 173.2 A 73.2 A apart
PV input
Max PV power 72.00 kW - Not published by Ginlong Solis
DC/AC ratio 1.20 - Not published by Ginlong Solis
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 160-1000 V 200-1000 V vs 160-1000 V
Start voltage 200 V 180 V -20 V for S6-GC60K-LV
MPP trackers 4 - Not published by Ginlong Solis
Strings per tracker 3 2 1 string apart
Max input current per tracker 28.5 A 42.0 A +13.5 A for S6-GC60K-LV
Efficiency
European efficiency 98.5 % 98.3 % +0.2 pp for Solis-60K-4G
Max efficiency 99.0 % 98.7 % +0.3 pp for Solis-60K-4G
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 63.0 kg 93.0 kg -30.0 kg for Solis-60K-4G
Weight per kW 1.1 kg/kW 1.6 kg/kW -0.5 kg/kW for Solis-60K-4G
Dimensions 700x630x357 mm 567x1014x345 mm 700x630x357 mm vs 567x1014x345 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Ginlong Solis
Integrated DC switch - Yes Not published by Ginlong Solis
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Solis-60K-4G vs Huawei SUN2000-60KTL-M0
9 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Solis-60K-4G vs Sungrow SG60KTL-182
10 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Solis-60K-4G vs GoodWe GW60KN-MT
6 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.