Ginlong Solis S6-GR1P2.5K vs Growatt MIN 2500TL-X
VS
The verdict
11 differences, and they point both ways
The largest is european efficiency: 0.6 pp more efficient. 12 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
12
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 23 parameters
What actually differs
Parameter
S6-GR1P2.5K
MIN 2500TL-X
Difference
European efficiency
96.5 %
97.1 %
0.6 pp more efficient
Max efficiency
97.3 %
98.2 %
0.9 pp more efficient
Max AC power
2.80 kW
2.50 kW
0.30 kW apart
Noise
20 dB
35 dB
15 dB quieter
Max PV power
3.75 kW
3.50 kW
0.25 kW apart
DC/AC ratio
1.50
1.40
0.10 more oversizing headroom
Max AC current
13.3 A
11.3 A
2.0 A apart
Start voltage
60 V
100 V
40 V earlier start
Max input current per tracker
14.0 A
13.5 A
0.5 A more headroom
Ingress protection
IP66
IP65
IP66 vs IP65
Dimensions
543x310x160 mm
350x375x160 mm
543x310x160 mm vs 350x375x160 mm
02
Full specification
Parameter
S6-GR1P2.5K
MIN 2500TL-X
Difference
AC output
Rated AC power
2.50 kW
2.50 kW
Same
Max AC power
2.80 kW
2.50 kW
0.30 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
13.3 A
11.3 A
2.0 A apart
PV input
Max PV power
3.75 kW
3.50 kW
0.25 kW apart
DC/AC ratio
1.50
1.40
+0.10 for S6-GR1P2.5K
Max DC voltage
600 V
-
Not published by Growatt
MPPT voltage range
50-520 V
-
Not published by Growatt
Start voltage
60 V
100 V
-40 V for S6-GR1P2.5K
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
14.0 A
13.5 A
+0.5 A for S6-GR1P2.5K
Efficiency
European efficiency
96.5 %
97.1 %
+0.6 pp for MIN 2500TL-X
Max efficiency
97.3 %
98.2 %
+0.9 pp for MIN 2500TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
11.0 kg
10.8 kg
Effectively the same
Weight per kW
4.4 kg/kW
4.3 kg/kW
Effectively the same
Dimensions
543x310x160 mm
350x375x160 mm
543x310x160 mm vs 350x375x160 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
20 dB
35 dB
-15 dB for S6-GR1P2.5K
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Ginlong Solis S6-GR1P2.5K vs Growatt 2500-S
16 differences, the largest is european efficiency
Same type, similar size
Sungrow
Ginlong Solis S6-GR1P2.5K vs Sungrow SG2.5RS-S
12 differences, the largest is european efficiency
Same type, similar size
GoodWe
Ginlong Solis S6-GR1P2.5K vs GoodWe GW2500-XS
13 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MIN 2500TL-X vs Growatt MIC 2500TL-X
8 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.