Ginlong Solis S6-GR1P2.5K vs Growatt 2500-S
VS
The verdict
Growatt 2500-S leads on the differences that matter
The largest is european efficiency: 0.8 pp more efficient. 8 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
8
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 24 parameters
What actually differs
Parameter
S6-GR1P2.5K
Growatt 2500-S
Difference
European efficiency
96.5 %
97.3 %
0.8 pp more efficient
Max DC voltage
600 V
550 V
50 V apart
Max AC power
2.80 kW
2.50 kW
0.30 kW apart
Max PV power
3.75 kW
3.25 kW
0.50 kW apart
DC/AC ratio
1.50
1.30
0.20 more oversizing headroom
Weight per kW
4.4 kg/kW
3.6 kg/kW
0.8 kg/kW lighter
Weight
11.0 kg
9.1 kg
1.9 kg lighter
Max input current per tracker
14.0 A
13.0 A
1.0 A more headroom
Noise
20 dB
25 dB
5 dB quieter
Max efficiency
97.3 %
97.6 %
0.3 pp more efficient
MPP trackers
2
1
1 tracker more
Ingress protection
IP66
IP65
IP66 vs IP65
Max AC current
13.3 A
11.9 A
1.4 A apart
MPPT voltage range
50-520 V
50-550 V
50-520 V vs 50-550 V
Start voltage
60 V
50 V
10 V earlier start
Dimensions
543x310x160 mm
359x271x141 mm
543x310x160 mm vs 359x271x141 mm
02
Full specification
Parameter
S6-GR1P2.5K
Growatt 2500-S
Difference
AC output
Rated AC power
2.50 kW
2.50 kW
Same
Max AC power
2.80 kW
2.50 kW
0.30 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
13.3 A
11.9 A
1.4 A apart
PV input
Max PV power
3.75 kW
3.25 kW
0.50 kW apart
DC/AC ratio
1.50
1.30
+0.20 for S6-GR1P2.5K
Max DC voltage
600 V
550 V
50 V apart
MPPT voltage range
50-520 V
50-550 V
50-520 V vs 50-550 V
Start voltage
60 V
50 V
-10 V for Growatt 2500-S
MPP trackers
2
1
+1 trackers for S6-GR1P2.5K
Strings per tracker
1
1
Same
Max input current per tracker
14.0 A
13.0 A
+1.0 A for S6-GR1P2.5K
Efficiency
European efficiency
96.5 %
97.3 %
+0.8 pp for Growatt 2500-S
Max efficiency
97.3 %
97.6 %
+0.3 pp for Growatt 2500-S
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
11.0 kg
9.1 kg
-1.9 kg for Growatt 2500-S
Weight per kW
4.4 kg/kW
3.6 kg/kW
-0.8 kg/kW for Growatt 2500-S
Dimensions
543x310x160 mm
359x271x141 mm
543x310x160 mm vs 359x271x141 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
20 dB
25 dB
-5 dB for S6-GR1P2.5K
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Sungrow
Ginlong Solis S6-GR1P2.5K vs Sungrow SG2.5RS-S
12 differences, the largest is european efficiency
Same type, similar size
GoodWe
Ginlong Solis S6-GR1P2.5K vs GoodWe GW2500-XS
13 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis S6-GR1P2.5K vs Growatt MIN 2500TL-X
11 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt 2500-S vs Growatt MIC 2500TL-X
6 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.