Ginlong Solis S6-GC50K-LV vs Growatt MAX 50KTL3 LV
VS
The verdict
S6-GC50K-LV leads on the differences that matter
The largest is max input current per tracker: 16.0 A more headroom. 11 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
11
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 20 parameters
What actually differs
Parameter
S6-GC50K-LV
MAX 50KTL3 LV
Difference
Max input current per tracker
42.0 A
26.0 A
16.0 A more headroom
Max AC power
55.00 kW
55.50 kW
0.50 kW apart
Weight
90.0 kg
82.0 kg
8.0 kg lighter
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
144.3 A
80.5 A
63.8 A apart
Start voltage
180 V
250 V
70 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
160-1000 V
200-1000 V
160-1000 V vs 200-1000 V
Dimensions
567x1014x345 mm
600x860x300 mm
567x1014x345 mm vs 600x860x300 mm
02
Full specification
Parameter
S6-GC50K-LV
MAX 50KTL3 LV
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
55.00 kW
55.50 kW
0.50 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
144.3 A
80.5 A
63.8 A apart
PV input
Max PV power
-
75.00 kW
Not published by Ginlong Solis
DC/AC ratio
-
1.50
Not published by Ginlong Solis
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
160-1000 V
200-1000 V
160-1000 V vs 200-1000 V
Start voltage
180 V
250 V
-70 V for S6-GC50K-LV
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
42.0 A
26.0 A
+16.0 A for S6-GC50K-LV
Efficiency
European efficiency
98.3 %
98.4 %
Effectively the same
Max efficiency
98.7 %
98.8 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
90.0 kg
82.0 kg
-8.0 kg for MAX 50KTL3 LV
Weight per kW
1.8 kg/kW
1.6 kg/kW
Effectively the same
Dimensions
567x1014x345 mm
600x860x300 mm
567x1014x345 mm vs 600x860x300 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Ginlong Solis S6-GC50K-LV vs Huawei SUN2000-50KTL-JPM0
12 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Ginlong Solis S6-GC50K-LV vs Huawei SUN2000-50KTL-M0
11 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GC50K-LV vs Solis-50K-HV
10 differences, the largest is weight
Same type, similar size
Sungrow
Growatt MAX 50KTL3 LV vs Sungrow SG50CX
6 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.