Ginlong Solis S6-GC3P150K07-NV-ND vs Growatt MAX 150KTL3-X MV
VS
The verdict
MAX 150KTL3-X MV leads on the differences that matter
The largest is mpp trackers: 3 trackers more. 9 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
9
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 20 parameters
What actually differs
Parameter
S6-GC3P150K07-NV-ND
MAX 150KTL3-X MV
Difference
MPP trackers
7
10
3 trackers more
Max input current per tracker
54.0 A
32.0 A
22.0 A more headroom
Max AC power
165.00 kW
150.00 kW
15.00 kW apart
Weight
105.0 kg
84.0 kg
21.0 kg lighter
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
250.6 A
198.5 A
52.1 A apart
Max efficiency
98.8 %
99.0 %
0.2 pp more efficient
MPPT voltage range
160-1000 V
180-1000 V
160-1000 V vs 180-1000 V
Start voltage
180 V
195 V
15 V earlier start
Strings per tracker
3
2
1 string apart
Dimensions
869x1036x396 mm
640x970x345 mm
869x1036x396 mm vs 640x970x345 mm
02
Full specification
Parameter
S6-GC3P150K07-NV-ND
MAX 150KTL3-X MV
Difference
AC output
Rated AC power
150.00 kW
150.00 kW
Same
Max AC power
165.00 kW
150.00 kW
15.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
250.6 A
198.5 A
52.1 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
160-1000 V
180-1000 V
160-1000 V vs 180-1000 V
Start voltage
180 V
195 V
-15 V for S6-GC3P150K07-NV-ND
MPP trackers
7
10
+3 trackers for MAX 150KTL3-X MV
Strings per tracker
3
2
1 string apart
Max input current per tracker
54.0 A
32.0 A
+22.0 A for S6-GC3P150K07-NV-ND
Efficiency
European efficiency
98.3 %
-
Not published by Growatt
Max efficiency
98.8 %
99.0 %
+0.2 pp for MAX 150KTL3-X MV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
105.0 kg
84.0 kg
-21.0 kg for MAX 150KTL3-X MV
Weight per kW
0.7 kg/kW
0.6 kg/kW
Effectively the same
Dimensions
869x1036x396 mm
640x970x345 mm
869x1036x396 mm vs 640x970x345 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
SMA Solar
Ginlong Solis S6-GC3P150K07-NV-ND vs SMA Solar Sunny Highpower PEAK3 SHP 150-21
10 differences, the largest is mpp trackers
Same type, similar size
SMA Solar
Ginlong Solis S6-GC3P150K07-NV-ND vs SMA Solar Sunny Highpower Storage SHPS 150-21
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis S6-GC3P150K07-NV-ND vs Growatt MAX 150KTL3-X LV
7 differences, the largest is mpp trackers
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.