Ginlong Solis S6-GC3P150K07-NV-ND vs SMA Solar Sunny Highpower PEAK3 SHP 150-21
VS

SMA Solar
Sunny Highpower PEAK3 SHP 150-21
150 kW
98.8 % euro
Grid-tie
The verdict
Sunny Highpower PEAK3 SHP 150-21 leads on the differences that matter
The largest is mpp trackers: 6 trackers more. 5 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
5
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 15 parameters
What actually differs
Parameter
S6-GC3P150K07-NV-ND
Sunny Highpower PEAK3 SHP 150-21
Difference
MPP trackers
7
1
6 trackers more
European efficiency
98.3 %
98.8 %
0.5 pp more efficient
Max DC voltage
1100 V
1500 V
400 V apart
Max input current per tracker
54.0 A
180.0 A
126.0 A more headroom
Max AC power
165.00 kW
150.00 kW
15.00 kW apart
Weight
105.0 kg
99.0 kg
6.0 kg lighter
Max efficiency
98.8 %
99.1 %
0.3 pp more efficient
Max AC current
250.6 A
151.0 A
99.6 A apart
Ingress protection
IP66
IP65
IP66 vs IP65
Dimensions
869x1036x396 mm
830x770x462 mm
869x1036x396 mm vs 830x770x462 mm
02
Full specification
Parameter
S6-GC3P150K07-NV-ND
Sunny Highpower PEAK3 SHP 150-21
Difference
AC output
Rated AC power
150.00 kW
150.00 kW
Same
Max AC power
165.00 kW
150.00 kW
15.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
-
Not published by SMA Solar
Max AC current
250.6 A
151.0 A
99.6 A apart
PV input
Max PV power
-
300.00 kW
Not published by Ginlong Solis
DC/AC ratio
-
2.00
Not published by Ginlong Solis
Max DC voltage
1100 V
1500 V
400 V apart
MPPT voltage range
160-1000 V
-
Not published by SMA Solar
Start voltage
180 V
-
Not published by SMA Solar
MPP trackers
7
1
+6 trackers for S6-GC3P150K07-NV-ND
Strings per tracker
3
-
Not published by SMA Solar
Max input current per tracker
54.0 A
180.0 A
+126.0 A for Sunny Highpower PEAK3 SHP 150-21
Efficiency
European efficiency
98.3 %
98.8 %
+0.5 pp for Sunny Highpower PEAK3 SHP 150-21
Max efficiency
98.8 %
99.1 %
+0.3 pp for Sunny Highpower PEAK3 SHP 150-21
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
105.0 kg
99.0 kg
-6.0 kg for Sunny Highpower PEAK3 SHP 150-21
Weight per kW
0.7 kg/kW
0.7 kg/kW
Same
Dimensions
869x1036x396 mm
830x770x462 mm
869x1036x396 mm vs 830x770x462 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
forced-air
Same
Noise
-
69 dB
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by SMA Solar
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
Yes
-
Not published by SMA Solar
Integrated DC switch
Yes
-
Not published by SMA Solar
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
SMA Solar
Ginlong Solis S6-GC3P150K07-NV-ND vs SMA Solar Sunny Highpower Storage SHPS 150-21
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis S6-GC3P150K07-NV-ND vs Growatt MAX 150KTL3-X LV
7 differences, the largest is mpp trackers
Same type, similar size
Sungrow
Ginlong Solis S6-GC3P150K07-NV-ND vs Sungrow SG150CX
6 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.