Ginlong Solis S6-GC3P100K07-LV-ND vs SMA Solar Sunny Highpower PEAK3 SHP 100-21
VS

SMA Solar
Sunny Highpower PEAK3 SHP 100-21
100 kW
98.5 % euro
Grid-tie
The verdict
Sunny Highpower PEAK3 SHP 100-21 leads on the differences that matter
The largest is mpp trackers: 6 trackers more. 7 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
7
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 15 parameters
What actually differs
Parameter
S6-GC3P100K07-LV-ND
Sunny Highpower PEAK3 SHP 100-21
Difference
MPP trackers
7
1
6 trackers more
Max DC voltage
800 V
1500 V
700 V apart
Max input current per tracker
54.0 A
180.0 A
126.0 A more headroom
Weight
105.0 kg
99.0 kg
6.0 kg lighter
European efficiency
98.3 %
98.5 %
0.2 pp more efficient
Max AC current
251.0 A
151.0 A
100.0 A apart
Ingress protection
IP66
IP65
IP66 vs IP65
Dimensions
869x1036x396 mm
830x770x462 mm
869x1036x396 mm vs 830x770x462 mm
02
Full specification
Parameter
S6-GC3P100K07-LV-ND
Sunny Highpower PEAK3 SHP 100-21
Difference
AC output
Rated AC power
100.00 kW
100.00 kW
Same
Max AC power
100.00 kW
100.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
230 V
-
Not published by SMA Solar
Max AC current
251.0 A
151.0 A
100.0 A apart
PV input
Max PV power
-
200.00 kW
Not published by Ginlong Solis
DC/AC ratio
-
2.00
Not published by Ginlong Solis
Max DC voltage
800 V
1500 V
700 V apart
MPPT voltage range
160-800 V
-
Not published by SMA Solar
Start voltage
180 V
-
Not published by SMA Solar
MPP trackers
7
1
+6 trackers for S6-GC3P100K07-LV-ND
Strings per tracker
3
-
Not published by SMA Solar
Max input current per tracker
54.0 A
180.0 A
+126.0 A for Sunny Highpower PEAK3 SHP 100-21
Efficiency
European efficiency
98.3 %
98.5 %
+0.2 pp for Sunny Highpower PEAK3 SHP 100-21
Max efficiency
98.8 %
98.8 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
105.0 kg
99.0 kg
-6.0 kg for Sunny Highpower PEAK3 SHP 100-21
Weight per kW
1.1 kg/kW
1.0 kg/kW
Effectively the same
Dimensions
869x1036x396 mm
830x770x462 mm
869x1036x396 mm vs 830x770x462 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
forced-air
Same
Noise
-
69 dB
Not published by Ginlong Solis
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
-
Neither datasheet publishes this
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
-
Not published by SMA Solar
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Ginlong Solis S6-GC3P100K07-LV-ND vs Huawei SUN2000-100KTL-M2
12 differences, the largest is max dc voltage
Same type, similar size
Huawei
Ginlong Solis S6-GC3P100K07-LV-ND vs Huawei SUN2000-100KTL-M1 (@480 V)
11 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Ginlong Solis S6-GC3P100K07-LV-ND vs Sungrow SG110CX
12 differences, the largest is max dc voltage
Same type, similar size
SMA Solar
SMA Solar Sunny Highpower PEAK3 SHP 100-21 vs SMA Solar Sunny Highpower Storage SHPS 100-21
The same specification on paper
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.