Ginlong Solis S6-GC125K vs Sungrow SG125CX-P2
VS
The verdict
8 differences, and they point both ways
The largest is max input current per tracker: 12.0 A more headroom. 13 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
13
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 21 parameters
What actually differs
Parameter
S6-GC125K
SG125CX-P2
Difference
Max input current per tracker
42.0 A
30.0 A
12.0 A more headroom
MPP trackers
10
12
2 trackers more
Weight
96.0 kg
93.0 kg
3.0 kg lighter
Max AC current
189.9 A
181.1 A
8.8 A apart
Max efficiency
98.7 %
98.5 %
0.2 pp more efficient
MPPT voltage range
160-1000 V
180-1000 V
160-1000 V vs 180-1000 V
Start voltage
180 V
200 V
20 V earlier start
Dimensions
567x1014x345 mm
795x1020x360 mm
567x1014x345 mm vs 795x1020x360 mm
02
Full specification
Parameter
S6-GC125K
SG125CX-P2
Difference
AC output
Rated AC power
125.00 kW
125.00 kW
Same
Max AC power
125.00 kW
125.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
189.9 A
181.1 A
8.8 A apart
PV input
Max PV power
-
175.00 kW
Not published by Ginlong Solis
DC/AC ratio
-
1.40
Not published by Ginlong Solis
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
160-1000 V
180-1000 V
160-1000 V vs 180-1000 V
Start voltage
180 V
200 V
-20 V for S6-GC125K
MPP trackers
10
12
+2 trackers for SG125CX-P2
Strings per tracker
2
2
Same
Max input current per tracker
42.0 A
30.0 A
+12.0 A for S6-GC125K
Efficiency
European efficiency
98.3 %
98.3 %
Same
Max efficiency
98.7 %
98.5 %
+0.2 pp for S6-GC125K
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
96.0 kg
93.0 kg
-3.0 kg for SG125CX-P2
Weight per kW
0.8 kg/kW
0.7 kg/kW
Effectively the same
Dimensions
567x1014x345 mm
795x1020x360 mm
567x1014x345 mm vs 795x1020x360 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Sungrow
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GC125K vs Ginlong Solis S5-GC125K-HV
9 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Ginlong Solis S6-GC125K vs Growatt MAX 125KTL3-X LV
7 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Ginlong Solis S6-GC125K vs SOFAR 125KTLX-G4-A
5 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.