Skip to main content
S6-GC125K vs S5-GC125K-HV 13 of 22 identical Swap Change inverters

Ginlong Solis S6-GC125K vs Ginlong Solis S5-GC125K-HV

Ginlong Solis S6-GC125K
Ginlong Solis
S6-GC125K
125 kW 98.3 % euro Grid-tie
VS
Ginlong Solis S5-GC125K-HV
Ginlong Solis
S5-GC125K-HV
125 kW 98.6 % euro Grid-tie
The verdict

9 differences, and they point both ways

The largest is max input current per tracker: 10.0 A more headroom. 13 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
13 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 22 parameters
Parameter S6-GC125K S5-GC125K-HV Difference
Max input current per tracker 42.0 A 32.0 A 10.0 A more headroom
Max AC power 125.00 kW 137.50 kW 12.50 kW apart
Weight 96.0 kg 91.0 kg 5.0 kg lighter
European efficiency 98.3 % 98.6 % 0.3 pp more efficient
Max efficiency 98.7 % 99.0 % 0.3 pp more efficient
Max AC current 189.9 A 165.4 A 24.5 A apart
MPPT voltage range 160-1000 V 180-1000 V 160-1000 V vs 180-1000 V
Start voltage 180 V 195 V 15 V earlier start
Dimensions 567x1014x345 mm 567x1065x344 mm 567x1014x345 mm vs 567x1065x344 mm
02

Full specification

Parameter S6-GC125K S5-GC125K-HV Difference
AC output
Rated AC power 125.00 kW 125.00 kW Same
Max AC power 125.00 kW 137.50 kW 12.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 189.9 A 165.4 A 24.5 A apart
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 160-1000 V 180-1000 V 160-1000 V vs 180-1000 V
Start voltage 180 V 195 V -15 V for S6-GC125K
MPP trackers 10 10 Same
Strings per tracker 2 2 Same
Max input current per tracker 42.0 A 32.0 A +10.0 A for S6-GC125K
Efficiency
European efficiency 98.3 % 98.6 % +0.3 pp for S5-GC125K-HV
Max efficiency 98.7 % 99.0 % +0.3 pp for S5-GC125K-HV
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 96.0 kg 91.0 kg -5.0 kg for S5-GC125K-HV
Weight per kW 0.8 kg/kW 0.7 kg/kW Effectively the same
Dimensions 567x1014x345 mm 567x1065x344 mm 567x1014x345 mm vs 567x1065x344 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Ginlong Solis S6-GC125K vs Growatt MAX 125KTL3-X LV
7 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Ginlong Solis S6-GC125K vs Sungrow SG125CX-P2
8 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Ginlong Solis S6-GC125K vs SOFAR 125KTLX-G4-A
5 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.