Skip to main content
S6-GC110K vs Solis-110K-HV-5G 12 of 21 identical Swap Change inverters

Ginlong Solis S6-GC110K vs Solis-110K-HV-5G

Ginlong Solis S6-GC110K
Ginlong Solis
S6-GC110K
110 kW 98.3 % euro Grid-tie
VS
Solis-110K-HV-5G
Ginlong Solis
Solis-110K-HV-5G
110 kW 98.5 % euro Grid-tie
The verdict

9 differences, and they point both ways

The largest is max input current per tracker: 16.0 A more headroom. 12 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
12 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 21 parameters
Parameter S6-GC110K Solis-110K-HV-5G Difference
Max input current per tracker 42.0 A 26.0 A 16.0 A more headroom
Weight 96.0 kg 82.0 kg 14.0 kg lighter
European efficiency 98.3 % 98.5 % 0.2 pp more efficient
Max efficiency 98.7 % 99.0 % 0.3 pp more efficient
Max AC current 183.8 A 129.4 A 54.4 A apart
MPP trackers 10 9 1 tracker more
MPPT voltage range 160-1000 V 180-1000 V 160-1000 V vs 180-1000 V
Start voltage 180 V 195 V 15 V earlier start
Dimensions 567x1014x345 mm 567x1050x314 mm 567x1014x345 mm vs 567x1050x314 mm
02

Full specification

Parameter S6-GC110K Solis-110K-HV-5G Difference
AC output
Rated AC power 110.00 kW 110.00 kW Same
Max AC power 121.00 kW 121.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 183.8 A 129.4 A 54.4 A apart
PV input
Max PV power - 140.00 kW Not published by Ginlong Solis
DC/AC ratio - 1.27 Not published by Ginlong Solis
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 160-1000 V 180-1000 V 160-1000 V vs 180-1000 V
Start voltage 180 V 195 V -15 V for S6-GC110K
MPP trackers 10 9 +1 trackers for S6-GC110K
Strings per tracker 2 2 Same
Max input current per tracker 42.0 A 26.0 A +16.0 A for S6-GC110K
Efficiency
European efficiency 98.3 % 98.5 % +0.2 pp for Solis-110K-HV-5G
Max efficiency 98.7 % 99.0 % +0.3 pp for Solis-110K-HV-5G
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 96.0 kg 82.0 kg -14.0 kg for Solis-110K-HV-5G
Weight per kW 0.9 kg/kW 0.7 kg/kW Effectively the same
Dimensions 567x1014x345 mm 567x1050x314 mm 567x1014x345 mm vs 567x1050x314 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Ginlong Solis
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Ginlong Solis S6-GC110K vs Ginlong Solis S5-GC110K
7 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Ginlong Solis S6-GC110K vs Growatt MAX 110KTL3-X LV
7 differences, the largest is max input current per tracker
Same type, similar size
SMA Solar
Ginlong Solis S6-GC110K vs SMA Solar Sunny Tripower CORE2 STP 110-60
8 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Solis-110K-HV-5G vs SOFAR 125KTLX-G4
8 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.