Ginlong Solis S6-EH3P50K-H vs Growatt WIT 50K-HU-US
VS
The verdict
S6-EH3P50K-H leads on the differences that matter
The largest is max dc voltage: 100 V apart. 6 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
6
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 21 parameters
What actually differs
Parameter
S6-EH3P50K-H
WIT 50K-HU-US
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
40.0 A
32.0 A
8.0 A more headroom
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Max PV power
96.00 kW
109.20 kW
13.20 kW apart
DC/AC ratio
1.92
2.18
0.26 more oversizing headroom
Weight
73.0 kg
153.0 kg
80.0 kg lighter
Weight per kW
1.5 kg/kW
3.1 kg/kW
1.6 kg/kW lighter
Max efficiency
97.8 %
98.2 %
0.4 pp more efficient
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
76.0 A
66.2 A
9.8 A apart
Ingress protection
IP66
IP66/NEMA 4X
IP66 vs IP66/NEMA 4X
MPPT voltage range
150-850 V
180-800 V
150-850 V vs 180-800 V
Battery voltage
150-800 V
750-1000V for 3P3W / 820-1000V for 3P4W
150-800 V vs 750-1000V for 3P3W / 820-1000V for 3P4W
Start voltage
180 V
195 V
15 V earlier start
Dimensions
880x530x290 mm
1350x850x510 mm
880x530x290 mm vs 1350x850x510 mm
02
Full specification
Parameter
S6-EH3P50K-H
WIT 50K-HU-US
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
76.0 A
66.2 A
9.8 A apart
PV input
Max PV power
96.00 kW
109.20 kW
13.20 kW apart
DC/AC ratio
1.92
2.18
+0.26 for WIT 50K-HU-US
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
150-850 V
180-800 V
150-850 V vs 180-800 V
Start voltage
180 V
195 V
-15 V for S6-EH3P50K-H
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
2
Same
Max input current per tracker
40.0 A
32.0 A
+8.0 A for S6-EH3P50K-H
Efficiency
European efficiency
97.4 %
-
Not published by Growatt
Max efficiency
97.8 %
98.2 %
+0.4 pp for WIT 50K-HU-US
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
150-800 V
750-1000V for 3P3W / 820-1000V for 3P4W
150-800 V vs 750-1000V for 3P3W / 820-1000V for 3P4W
Max charge current
140 A
-
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
73.0 kg
153.0 kg
-80.0 kg for S6-EH3P50K-H
Weight per kW
1.5 kg/kW
3.1 kg/kW
-1.6 kg/kW for S6-EH3P50K-H
Dimensions
880x530x290 mm
1350x850x510 mm
880x530x290 mm vs 1350x850x510 mm
Ingress protection
IP66
IP66/NEMA 4X
IP66 vs IP66/NEMA 4X
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
Yes
-
Not published by Growatt
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
-
5 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Ginlong Solis S6-EH3P50K-H vs GoodWe GW50K-ET-10
14 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Ginlong Solis S6-EH3P50K-H vs Growatt MID 50K-HU
11 differences, the largest is max efficiency
Same type, similar size
Deye
Ginlong Solis S6-EH3P50K-H vs Deye SUN-50K-SG01HP3-EU-BM4
12 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.

