Skip to main content
S6-EH3P50K-H vs WIT 50K-H / WIT 50K-HU 7 of 21 identical Swap Change inverters

Ginlong Solis S6-EH3P50K-H vs Growatt WIT 50K-H / WIT 50K-HU

Ginlong Solis S6-EH3P50K-H
Ginlong Solis
S6-EH3P50K-H
50 kW 97.4 % euro Hybrid
VS
Growatt WIT 50K-H / WIT 50K-HU
Growatt
WIT 50K-H / WIT 50K-HU
50 kW Hybrid
The verdict

S6-EH3P50K-H leads on the differences that matter

The largest is max dc voltage: 100 V apart. 7 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
7 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 21 parameters
Parameter S6-EH3P50K-H WIT 50K-H / WIT 50K-HU Difference
Max DC voltage 1000 V 1100 V 100 V apart
Max input current per tracker 40.0 A 32.0 A 8.0 A more headroom
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Max PV power 96.00 kW 109.20 kW 13.20 kW apart
DC/AC ratio 1.92 2.18 0.26 more oversizing headroom
Weight 73.0 kg 133.0 kg 60.0 kg lighter
Weight per kW 1.5 kg/kW 2.7 kg/kW 1.2 kg/kW lighter
Max AC current 76.0 A 83.3 A 7.3 A apart
Max efficiency 97.8 % 98.0 % 0.2 pp more efficient
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 150-850 V 180-800 V 150-850 V vs 180-800 V
Battery voltage 150-800 V 600~1000V (for 3P3W) / 680~1000V (for 3P4W) 150-800 V vs 600~1000V (for 3P3W) / 680~1000V (for 3P4W)
Start voltage 180 V 195 V 15 V earlier start
Dimensions 880x530x290 mm 1350x820x510 mm 880x530x290 mm vs 1350x820x510 mm
02

Full specification

Parameter S6-EH3P50K-H WIT 50K-H / WIT 50K-HU Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 50.00 kW 55.00 kW 5.00 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 76.0 A 83.3 A 7.3 A apart
PV input
Max PV power 96.00 kW 109.20 kW 13.20 kW apart
DC/AC ratio 1.92 2.18 +0.26 for WIT 50K-H / WIT 50K-HU
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 150-850 V 180-800 V 150-850 V vs 180-800 V
Start voltage 180 V 195 V -15 V for S6-EH3P50K-H
MPP trackers - - Neither datasheet publishes this
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 32.0 A +8.0 A for S6-EH3P50K-H
Efficiency
European efficiency 97.4 % - Not published by Growatt
Max efficiency 97.8 % 98.0 % +0.2 pp for WIT 50K-H / WIT 50K-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 150-800 V 600~1000V (for 3P3W) / 680~1000V (for 3P4W) 150-800 V vs 600~1000V (for 3P3W) / 680~1000V (for 3P4W)
Max charge current 140 A - Not published by Growatt
Backup power - - Neither datasheet publishes this
Physical
Weight 73.0 kg 133.0 kg -60.0 kg for S6-EH3P50K-H
Weight per kW 1.5 kg/kW 2.7 kg/kW -1.2 kg/kW for S6-EH3P50K-H
Dimensions 880x530x290 mm 1350x820x510 mm 880x530x290 mm vs 1350x820x510 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - Yes Not published by Ginlong Solis
Ethernet Yes - Not published by Growatt
Arc fault protection - Yes Not published by Ginlong Solis
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty - 5 yrs Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Ginlong Solis S6-EH3P50K-H vs GoodWe GW50K-ET-10
14 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Ginlong Solis S6-EH3P50K-H vs Growatt MID 50K-HU
11 differences, the largest is max efficiency
Same type, similar size
Deye
Ginlong Solis S6-EH3P50K-H vs Deye SUN-50K-SG01HP3-EU-BM4
12 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.