Ginlong Solis S6-EH3P50K-H vs Growatt WIT 50K-AU-US
VS
The verdict
10 differences, and they point both ways
The largest is max ac power: 5.00 kW apart. 6 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
6
of 16 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 16 parameters
What actually differs
Parameter
S6-EH3P50K-H
WIT 50K-AU-US
Difference
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Max charge current
140 A
151 A
11 A faster charging
Weight
73.0 kg
140.0 kg
67.0 kg lighter
Weight per kW
1.5 kg/kW
2.8 kg/kW
1.3 kg/kW lighter
Max efficiency
97.8 %
98.2 %
0.4 pp more efficient
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
76.0 A
66.2 A
9.8 A apart
Ingress protection
IP66
IP66/NEMA 4X
IP66 vs IP66/NEMA 4X
Battery voltage
150-800 V
750-1000V for 3P3W / 820-1000V for 3P4W
150-800 V vs 750-1000V for 3P3W / 820-1000V for 3P4W
Dimensions
880x530x290 mm
1350x850x510 mm
880x530x290 mm vs 1350x850x510 mm
02
Full specification
Parameter
S6-EH3P50K-H
WIT 50K-AU-US
Difference
AC output
Rated AC power
50.00 kW
50.00 kW
Same
Max AC power
50.00 kW
55.00 kW
5.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
76.0 A
66.2 A
9.8 A apart
PV input
Max PV power
96.00 kW
-
Not published by Growatt
DC/AC ratio
1.92
-
Not published by Growatt
Max DC voltage
1000 V
-
Not published by Growatt
MPPT voltage range
150-850 V
-
Not published by Growatt
Start voltage
180 V
-
Not published by Growatt
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
2
-
Not published by Growatt
Max input current per tracker
40.0 A
-
Not published by Growatt
Efficiency
European efficiency
97.4 %
-
Not published by Growatt
Max efficiency
97.8 %
98.2 %
+0.4 pp for WIT 50K-AU-US
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
150-800 V
750-1000V for 3P3W / 820-1000V for 3P4W
150-800 V vs 750-1000V for 3P3W / 820-1000V for 3P4W
Max charge current
140 A
151 A
+11 A for WIT 50K-AU-US
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
73.0 kg
140.0 kg
-67.0 kg for S6-EH3P50K-H
Weight per kW
1.5 kg/kW
2.8 kg/kW
-1.3 kg/kW for S6-EH3P50K-H
Dimensions
880x530x290 mm
1350x850x510 mm
880x530x290 mm vs 1350x850x510 mm
Ingress protection
IP66
IP66/NEMA 4X
IP66 vs IP66/NEMA 4X
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
Yes
Yes
Same
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
-
10 yrs
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
GoodWe
Ginlong Solis S6-EH3P50K-H vs GoodWe GW50K-ET-10
14 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Ginlong Solis S6-EH3P50K-H vs Growatt MID 50K-HU
11 differences, the largest is max efficiency
Same type, similar size
Deye
Ginlong Solis S6-EH3P50K-H vs Deye SUN-50K-SG01HP3-EU-BM4
12 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.