Ginlong Solis S6-EH1P18K03-NV-YD-L vs Growatt WIT 18K-HU
VS
The verdict
WIT 18K-HU leads on the differences that matter
The largest is max dc voltage: 450 V apart. 10 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
10
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 23 parameters
What actually differs
Parameter
S6-EH1P18K03-NV-YD-L
WIT 18K-HU
Difference
Max DC voltage
550 V
1000 V
450 V apart
Max input current per tracker
20.0 A
40.0 A
20.0 A more headroom
Max PV power
28.80 kW
36.00 kW
7.20 kW apart
DC/AC ratio
1.60
2.00
0.40 more oversizing headroom
Noise
65 dB
55 dB
10 dB quieter
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Start voltage
100 V
180 V
80 V earlier start
MPP trackers
3
2
1 tracker more
MPPT voltage range
80-520 V
150-850 V
80-520 V vs 150-850 V
Battery voltage
40-60 V
40-60V
40-60 V vs 40-60V
Weight
55.5 kg
55.0 kg
0.5 kg lighter
Dimensions
845x459x313 mm
695x475x254 mm
845x459x313 mm vs 695x475x254 mm
02
Full specification
Parameter
S6-EH1P18K03-NV-YD-L
WIT 18K-HU
Difference
AC output
Rated AC power
18.00 kW
18.00 kW
Same
Max AC power
18.00 kW
18.00 kW
Same
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
81.8 A
-
Not published by Growatt
PV input
Max PV power
28.80 kW
36.00 kW
7.20 kW apart
DC/AC ratio
1.60
2.00
+0.40 for WIT 18K-HU
Max DC voltage
550 V
1000 V
450 V apart
MPPT voltage range
80-520 V
150-850 V
80-520 V vs 150-850 V
Start voltage
100 V
180 V
-80 V for S6-EH1P18K03-NV-YD-L
MPP trackers
3
2
+1 trackers for S6-EH1P18K03-NV-YD-L
Strings per tracker
2
2
Same
Max input current per tracker
20.0 A
40.0 A
+20.0 A for WIT 18K-HU
Efficiency
European efficiency
97.0 %
97.0 %
Same
Max efficiency
97.6 %
97.6 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
40-60 V
40-60V
40-60 V vs 40-60V
Max charge current
-
420 A
Not published by Ginlong Solis
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
55.5 kg
55.0 kg
-0.5 kg for WIT 18K-HU
Weight per kW
3.1 kg/kW
3.1 kg/kW
Same
Dimensions
845x459x313 mm
695x475x254 mm
845x459x313 mm vs 695x475x254 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
65 dB
55 dB
-10 dB for WIT 18K-HU
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
Yes
Not published by Ginlong Solis
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Fronius International
Ginlong Solis S6-EH1P18K03-NV-YD-L vs Fronius Verto 17.5 Plus
18 differences, the largest is rated ac power
Same type, similar size
Growatt
Ginlong Solis S6-EH1P18K03-NV-YD-L vs Growatt MID 17KTL3-XH
17 differences, the largest is rated ac power
Same type, similar size
Huawei
Ginlong Solis S6-EH1P18K03-NV-YD-L vs Huawei SUN5000-17K-MB0
18 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.