Ginlong Solis S6-EH1P18K03-NV-YD-L vs Fronius Verto 17.5 Plus
VS

Fronius International
Fronius Verto 17.5 Plus
17.5 kW
97.5 % euro
Hybrid
The verdict
Fronius Verto 17.5 Plus leads on the differences that matter
The largest is rated ac power: 0.50 kW apart. 6 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 18 differencesHow alike are they
6
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
18 of 24 parameters
What actually differs
Parameter
S6-EH1P18K03-NV-YD-L
Fronius Verto 17.5 Plus
Difference
Rated AC power
18.00 kW
17.50 kW
0.50 kW apart
European efficiency
97.0 %
97.5 %
0.5 pp more efficient
Max DC voltage
550 V
1000 V
450 V apart
Max input current per tracker
20.0 A
28.0 A
8.0 A more headroom
Max AC power
18.00 kW
17.50 kW
0.50 kW apart
Max PV power
28.80 kW
26.25 kW
2.55 kW apart
Weight
55.5 kg
43.0 kg
12.5 kg lighter
Noise
65 dB
57 dB
8 dB quieter
Max efficiency
97.6 %
98.1 %
0.5 pp more efficient
Weight per kW
3.1 kg/kW
2.5 kg/kW
0.6 kg/kW lighter
DC/AC ratio
1.60
1.50
0.10 more oversizing headroom
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
81.8 A
26.5 A
55.3 A apart
Start voltage
100 V
150 V
50 V earlier start
MPPT voltage range
80-520 V
150-870 V
80-520 V vs 150-870 V
Battery voltage
40-60 V
150-700
40-60 V vs 150-700
Dimensions
845x459x313 mm
865x574x279 mm
845x459x313 mm vs 865x574x279 mm
02
Full specification
Parameter
S6-EH1P18K03-NV-YD-L
Fronius Verto 17.5 Plus
Difference
AC output
Rated AC power
18.00 kW
17.50 kW
0.50 kW apart
Max AC power
18.00 kW
17.50 kW
0.50 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
81.8 A
26.5 A
55.3 A apart
PV input
Max PV power
28.80 kW
26.25 kW
2.55 kW apart
DC/AC ratio
1.60
1.50
+0.10 for S6-EH1P18K03-NV-YD-L
Max DC voltage
550 V
1000 V
450 V apart
MPPT voltage range
80-520 V
150-870 V
80-520 V vs 150-870 V
Start voltage
100 V
150 V
-50 V for S6-EH1P18K03-NV-YD-L
MPP trackers
3
3
Same
Strings per tracker
2
2
Same
Max input current per tracker
20.0 A
28.0 A
+8.0 A for Fronius Verto 17.5 Plus
Efficiency
European efficiency
97.0 %
97.5 %
+0.5 pp for Fronius Verto 17.5 Plus
Max efficiency
97.6 %
98.1 %
+0.5 pp for Fronius Verto 17.5 Plus
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
40-60 V
150-700
40-60 V vs 150-700
Max charge current
-
50 A
Not published by Ginlong Solis
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
55.5 kg
43.0 kg
-12.5 kg for Fronius Verto 17.5 Plus
Weight per kW
3.1 kg/kW
2.5 kg/kW
-0.6 kg/kW for Fronius Verto 17.5 Plus
Dimensions
845x459x313 mm
865x574x279 mm
845x459x313 mm vs 865x574x279 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
65 dB
57 dB
-8 dB for Fronius Verto 17.5 Plus
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
-
Yes
Not published by Ginlong Solis
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
-
Yes
Not published by Ginlong Solis
Integrated DC switch
-
Yes
Not published by Ginlong Solis
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Ginlong Solis S6-EH1P18K03-NV-YD-L vs Growatt WIT 18K-HU
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Ginlong Solis S6-EH1P18K03-NV-YD-L vs Growatt MID 17KTL3-XH
17 differences, the largest is rated ac power
Same type, similar size
Huawei
Ginlong Solis S6-EH1P18K03-NV-YD-L vs Huawei SUN5000-17K-MB0
18 differences, the largest is rated ac power
Same type, similar size
Huawei
Fronius Verto 17.5 Plus vs Huawei SUN2000-17K-MB0
17 differences, the largest is rated ac power
Same type, similar size
Growatt
Fronius Verto 17.5 Plus vs Growatt WIT 17K-XHU
14 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.