Skip to main content
RHI-4.6K-48ES-5G vs SUN2000L-4.6KTL 14 of 23 identical Swap Change inverters

Ginlong Solis RHI-4.6K-48ES-5G vs Huawei SUN2000L-4.6KTL

Ginlong Solis RHI-4.6K-48ES-5G
Ginlong Solis
RHI-4.6K-48ES-5G
4.6 kW 96.8 % euro Hybrid
VS
Huawei SUN2000L-4.6KTL
Huawei
SUN2000L-4.6KTL
4.6 kW 98.0 % euro Hybrid
The verdict

SUN2000L-4.6KTL leads on the differences that matter

The largest is european efficiency: 1.2 pp more efficient. 14 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 9 differences
How alike are they
14 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

9 of 23 parameters
Parameter RHI-4.6K-48ES-5G SUN2000L-4.6KTL Difference
European efficiency 96.8 % 98.0 % 1.2 pp more efficient
Max efficiency 97.5 % 98.6 % 1.1 pp more efficient
Max AC power 4.60 kW 5.00 kW 0.40 kW apart
Max charge current 100 A 10 A 90 A faster charging
Weight 17.0 kg 10.6 kg 6.4 kg lighter
Weight per kW 3.7 kg/kW 2.3 kg/kW 1.4 kg/kW lighter
MPPT voltage range 90-520 V 120-480 V 90-520 V vs 120-480 V
Battery voltage 42-58 V 350-450 Vdc 42-58 V vs 350-450 Vdc
Dimensions 505x333x249 mm 375x375x162 mm 505x333x249 mm vs 375x375x162 mm
02

Full specification

Parameter RHI-4.6K-48ES-5G SUN2000L-4.6KTL Difference
AC output
Rated AC power 4.60 kW 4.60 kW Same
Max AC power 4.60 kW 5.00 kW 0.40 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 23.0 A 23.0 A Same
PV input
Max PV power 8.00 kW - Not published by Huawei
DC/AC ratio 1.74 - Not published by Huawei
Max DC voltage 600 V 600 V Same
MPPT voltage range 90-520 V 120-480 V 90-520 V vs 120-480 V
Start voltage 120 V 120 V Same
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 11.0 A 11.0 A Same
Efficiency
European efficiency 96.8 % 98.0 % +1.2 pp for SUN2000L-4.6KTL
Max efficiency 97.5 % 98.6 % +1.1 pp for SUN2000L-4.6KTL
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 42-58 V 350-450 Vdc 42-58 V vs 350-450 Vdc
Max charge current 100 A 10 A +90 A for RHI-4.6K-48ES-5G
Backup power 5.0 kW - Not published by Huawei
Physical
Weight 17.0 kg 10.6 kg -6.4 kg for SUN2000L-4.6KTL
Weight per kW 3.7 kg/kW 2.3 kg/kW -1.4 kg/kW for SUN2000L-4.6KTL
Dimensions 505x333x249 mm 375x375x162 mm 505x333x249 mm vs 375x375x162 mm
Ingress protection IP65 IP65 Same
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Huawei
Integrated DC switch - Yes Not published by Ginlong Solis
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Ginlong Solis RHI-4.6K-48ES-5G vs Huawei SUN2000-4.6KTL-L1
14 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis RHI-4.6K-48ES-5G vs Growatt SPM 4600TL-HU
13 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis RHI-4.6K-48ES-5G vs Growatt MIN 4600TL-XH
14 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000L-4.6KTL vs Growatt MIN 4600TL-XA
7 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.