Ginlong Solis RHI-4.6K-48ES-5G vs Huawei SUN2000-4.6KTL-L1
VS
The verdict
SUN2000-4.6KTL-L1 leads on the differences that matter
The largest is european efficiency: 0.9 pp more efficient. 12 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
12
of 26 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 26 parameters
What actually differs
Parameter
RHI-4.6K-48ES-5G
SUN2000-4.6KTL-L1
Difference
European efficiency
96.8 %
97.7 %
0.9 pp more efficient
Max efficiency
97.5 %
98.4 %
0.9 pp more efficient
Max input current per tracker
11.0 A
12.5 A
1.5 A more headroom
Max AC power
4.60 kW
5.00 kW
0.40 kW apart
Max PV power
8.00 kW
6.90 kW
1.10 kW apart
DC/AC ratio
1.74
1.50
0.24 more oversizing headroom
Max charge current
100 A
15 A
85 A faster charging
Weight
17.0 kg
12.0 kg
5.0 kg lighter
Weight per kW
3.7 kg/kW
2.6 kg/kW
1.1 kg/kW lighter
Max AC current
23.0 A
20.9 A
2.1 A apart
MPPT voltage range
90-520 V
90-560 V
90-520 V vs 90-560 V
Start voltage
120 V
100 V
20 V earlier start
Battery voltage
42-58 V
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
42-58 V vs 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
Dimensions
505x333x249 mm
365x365x156 mm
505x333x249 mm vs 365x365x156 mm
02
Full specification
Parameter
RHI-4.6K-48ES-5G
SUN2000-4.6KTL-L1
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
4.60 kW
5.00 kW
0.40 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
23.0 A
20.9 A
2.1 A apart
PV input
Max PV power
8.00 kW
6.90 kW
1.10 kW apart
DC/AC ratio
1.74
1.50
+0.24 for RHI-4.6K-48ES-5G
Max DC voltage
600 V
600 V
Same
MPPT voltage range
90-520 V
90-560 V
90-520 V vs 90-560 V
Start voltage
120 V
100 V
-20 V for SUN2000-4.6KTL-L1
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
11.0 A
12.5 A
+1.5 A for SUN2000-4.6KTL-L1
Efficiency
European efficiency
96.8 %
97.7 %
+0.9 pp for SUN2000-4.6KTL-L1
Max efficiency
97.5 %
98.4 %
+0.9 pp for SUN2000-4.6KTL-L1
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
42-58 V
350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
42-58 V vs 350-450 Vdc (LG Chem RESU 7H_R/10H_R) or 350-560 Vdc (HUAWEI Smart ESS 5-30 kWh)
Max charge current
100 A
15 A
+85 A for RHI-4.6K-48ES-5G
Backup power
5.0 kW
-
Not published by Huawei
Physical
Weight
17.0 kg
12.0 kg
-5.0 kg for SUN2000-4.6KTL-L1
Weight per kW
3.7 kg/kW
2.6 kg/kW
-1.1 kg/kW for SUN2000-4.6KTL-L1
Dimensions
505x333x249 mm
365x365x156 mm
505x333x249 mm vs 365x365x156 mm
Ingress protection
IP65
IP65
Same
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Ginlong Solis
Arc fault protection
Yes
Yes
Same
Integrated DC switch
-
Yes
Not published by Ginlong Solis
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Ginlong Solis RHI-4.6K-48ES-5G vs Huawei SUN2000L-4.6KTL
9 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis RHI-4.6K-48ES-5G vs Growatt SPM 4600TL-HU
13 differences, the largest is european efficiency
Same type, similar size
Growatt
Ginlong Solis RHI-4.6K-48ES-5G vs Growatt MIN 4600TL-XH
14 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-4.6KTL-L1 vs Growatt MIN 4600TL-XA
7 differences, the largest is max ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.