Skip to main content
Fronius Symo GEN24 Plus 8.0 vs SUN5000-8K-MAP0 10 of 27 identical Swap Change inverters

Fronius Symo GEN24 Plus 8.0 vs Huawei SUN5000-8K-MAP0

Fronius Symo GEN24 Plus 8.0
Fronius International
Fronius Symo GEN24 Plus 8.0
8 kW 97.8 % euro Hybrid
VS
Huawei SUN5000-8K-MAP0
Huawei
SUN5000-8K-MAP0
8 kW 98.0 % euro Hybrid
The verdict

SUN5000-8K-MAP0 leads on the differences that matter

The largest is max dc voltage: 100 V apart. 10 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
10 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 27 parameters
Parameter Fronius Symo GEN24 Plus 8.0 SUN5000-8K-MAP0 Difference
Max DC voltage 1000 V 1100 V 100 V apart
Max input current per tracker 25.0 A 16.0 A 9.0 A more headroom
Max AC power 8.00 kW 8.80 kW 0.80 kW apart
Max PV power 8.26 kW 14.60 kW 6.34 kW apart
DC/AC ratio 1.03 1.82 0.79 more oversizing headroom
Weight 23.4 kg 21.0 kg 2.4 kg lighter
Noise 47 dB 29 dB 18 dB quieter
Max efficiency 98.2 % 98.6 % 0.4 pp more efficient
European efficiency 97.8 % 98.0 % 0.2 pp more efficient
Start voltage 80 V 160 V 80 V earlier start
Max charge current 22 A 20 A 2 A faster charging
Weight per kW 2.9 kg/kW 2.6 kg/kW 0.3 kg/kW lighter
Max AC current 12.1 A 13.3 A 1.2 A apart
MPPT voltage range 80-800 V 160-1000 V 80-800 V vs 160-1000 V
Battery voltage 160 - 700 600-980 V 160 - 700 vs 600-980 V
Dimensions 595x529x180 mm 490x460x130 mm 595x529x180 mm vs 490x460x130 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter Fronius Symo GEN24 Plus 8.0 SUN5000-8K-MAP0 Difference
AC output
Rated AC power 8.00 kW 8.00 kW Same
Max AC power 8.00 kW 8.80 kW 0.80 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 12.1 A 13.3 A 1.2 A apart
PV input
Max PV power 8.26 kW 14.60 kW 6.34 kW apart
DC/AC ratio 1.03 1.82 +0.79 for SUN5000-8K-MAP0
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 80-800 V 160-1000 V 80-800 V vs 160-1000 V
Start voltage 80 V 160 V -80 V for Fronius Symo GEN24 Plus 8.0
MPP trackers 2 2 Same
Strings per tracker - 1 Not published by Fronius International
Max input current per tracker 25.0 A 16.0 A +9.0 A for Fronius Symo GEN24 Plus 8.0
Efficiency
European efficiency 97.8 % 98.0 % +0.2 pp for SUN5000-8K-MAP0
Max efficiency 98.2 % 98.6 % +0.4 pp for SUN5000-8K-MAP0
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 160 - 700 600-980 V 160 - 700 vs 600-980 V
Max charge current 22 A 20 A +2 A for Fronius Symo GEN24 Plus 8.0
Backup power - - Neither datasheet publishes this
Physical
Weight 23.4 kg 21.0 kg -2.4 kg for SUN5000-8K-MAP0
Weight per kW 2.9 kg/kW 2.6 kg/kW -0.3 kg/kW for SUN5000-8K-MAP0
Dimensions 595x529x180 mm 490x460x130 mm 595x529x180 mm vs 490x460x130 mm
Ingress protection IP66 IP66 Same
Cooling forced-air natural forced-air vs natural
Noise 47 dB 29 dB -18 dB for SUN5000-8K-MAP0
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection - Yes Not published by Fronius International
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Fronius Symo GEN24 Plus 8.0 vs SolarEdge SE8000H
13 differences, the largest is european efficiency
Same type, similar size
Growatt
Fronius Symo GEN24 Plus 8.0 vs Growatt MOD 8000TL3-XH
15 differences, the largest is max dc voltage
Same type, similar size
Growatt
Fronius Symo GEN24 Plus 8.0 vs Growatt MOD 8000TL3-HU
16 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Huawei SUN5000-8K-MAP0 vs Huawei SUN2000-8KTL-M1
11 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.