Skip to main content
LSOLAR SML-II-5.6KW vs IGRID-VX-IV-5.6KW-WIFI 13 of 18 identical Swap Change inverters

Easun Power LSOLAR SML-II-5.6KW vs Easun Power IGRID-VX-IV-5.6KW-WIFI

Easun Power
LSOLAR SML-II-5.6KW
5.6 kW Off-grid
VS
Easun Power
IGRID-VX-IV-5.6KW-WIFI
5.6 kW Off-grid
The verdict

LSOLAR SML-II-5.6KW leads on the differences that matter

The largest is max input current per tracker: 78.0 A more headroom. 13 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 5 differences
How alike are they
13 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

5 of 18 parameters
Parameter LSOLAR SML-II-5.6KW IGRID-VX-IV-5.6KW-WIFI Difference
Max input current per tracker 100.0 A 22.0 A 78.0 A more headroom
Max efficiency 98.0 % 92.0 % 6.0 pp more efficient
Weight 12.0 kg 10.5 kg 1.5 kg lighter
Weight per kW 2.1 kg/kW 1.9 kg/kW 0.3 kg/kW lighter
Dimensions 300x100x440 mm 426x322x124 mm 300x100x440 mm vs 426x322x124 mm
02

Full specification

Parameter LSOLAR SML-II-5.6KW IGRID-VX-IV-5.6KW-WIFI Difference
AC output
Rated AC power 5.60 kW 5.60 kW Same
Max AC power 5.60 kW 5.60 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current - 24.0 A Not published by Easun Power
PV input
Max PV power 6.00 kW 6.00 kW Same
DC/AC ratio 1.07 1.07 Same
Max DC voltage 500 V 500 V Same
MPPT voltage range 120-450 V 120-450 V Same
Start voltage - 120 V Not published by Easun Power
MPP trackers 1 1 Same
Strings per tracker - - Neither datasheet publishes this
Max input current per tracker 100.0 A 22.0 A +78.0 A for LSOLAR SML-II-5.6KW
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 98.0 % 92.0 % +6.0 pp for LSOLAR SML-II-5.6KW
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage - 40-60 Vdc (rated 48V; minimum starting voltage 44V) Not published by Easun Power
Max charge current 100 A 100 A Same
Backup power - 5.6 kW Not published by Easun Power
Physical
Weight 12.0 kg 10.5 kg -1.5 kg for IGRID-VX-IV-5.6KW-WIFI
Weight per kW 2.1 kg/kW 1.9 kg/kW -0.3 kg/kW for IGRID-VX-IV-5.6KW-WIFI
Dimensions 300x100x440 mm 426x322x124 mm 300x100x440 mm vs 426x322x124 mm
Ingress protection IP21 - Not published by Easun Power
Cooling - forced-air Not published by Easun Power
Noise - 60 dB Not published by Easun Power
Max operating temperature 55 °C 55 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty 1 yrs - Not published by Easun Power
03

More useful comparisons

Open all inverters
Same type, similar size
Easun Power
Easun Power LSOLAR SML-II-5.6KW vs Easun Power ISOLAR-SMX-II-5.6KP-WIFI
6 differences, the largest is max input current per tracker
Same type, similar size
Easun Power
Easun Power LSOLAR SML-II-5.6KW vs Easun Power ISolar SMV IV 5600-48
The same specification on paper
Same type, similar size
Easun Power
Easun Power LSOLAR SML-II-5.6KW vs Easun Power ISolar SMG II 5.6KW
6 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.