Easun Power IGRID-VX-IV-5.6KW-WIFI vs Easun Power LSOLAR SML-II-5.6KW
VS
The verdict
LSOLAR SML-II-5.6KW leads on the differences that matter
The largest is max input current per tracker: 78.0 A more headroom. 13 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See all 5 differencesHow alike are they
13
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
5 of 18 parameters
What actually differs
Parameter
IGRID-VX-IV-5.6KW-WIFI
LSOLAR SML-II-5.6KW
Difference
Max input current per tracker
22.0 A
100.0 A
78.0 A more headroom
Max efficiency
92.0 %
98.0 %
6.0 pp more efficient
Weight
10.5 kg
12.0 kg
1.5 kg lighter
Weight per kW
1.9 kg/kW
2.1 kg/kW
0.3 kg/kW lighter
Dimensions
426x322x124 mm
300x100x440 mm
426x322x124 mm vs 300x100x440 mm
02
Full specification
Parameter
IGRID-VX-IV-5.6KW-WIFI
LSOLAR SML-II-5.6KW
Difference
AC output
Rated AC power
5.60 kW
5.60 kW
Same
Max AC power
5.60 kW
5.60 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
24.0 A
-
Not published by Easun Power
PV input
Max PV power
6.00 kW
6.00 kW
Same
DC/AC ratio
1.07
1.07
Same
Max DC voltage
500 V
500 V
Same
MPPT voltage range
120-450 V
120-450 V
Same
Start voltage
120 V
-
Not published by Easun Power
MPP trackers
1
1
Same
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
22.0 A
100.0 A
+78.0 A for LSOLAR SML-II-5.6KW
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
92.0 %
98.0 %
+6.0 pp for LSOLAR SML-II-5.6KW
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
40-60 Vdc (rated 48V; minimum starting voltage 44V)
-
Not published by Easun Power
Max charge current
100 A
100 A
Same
Backup power
5.6 kW
-
Not published by Easun Power
Physical
Weight
10.5 kg
12.0 kg
-1.5 kg for IGRID-VX-IV-5.6KW-WIFI
Weight per kW
1.9 kg/kW
2.1 kg/kW
-0.3 kg/kW for IGRID-VX-IV-5.6KW-WIFI
Dimensions
426x322x124 mm
300x100x440 mm
426x322x124 mm vs 300x100x440 mm
Ingress protection
-
IP21
Not published by Easun Power
Cooling
forced-air
-
Not published by Easun Power
Noise
60 dB
-
Not published by Easun Power
Max operating temperature
55 °C
55 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
-
Neither datasheet publishes this
Warranty
Warranty
-
1 yrs
Not published by Easun Power
03
Open all inverters
More useful comparisons
Same type, similar size
Easun Power
Easun Power IGRID-VX-IV-5.6KW-WIFI vs Easun Power ISOLAR-SMX-II-5.6KP-WIFI
3 differences, the largest is max charge current
Same type, similar size
Easun Power
Easun Power IGRID-VX-IV-5.6KW-WIFI vs Easun Power ISolar SMV IV 5600-48
The same specification on paper
Same type, similar size
Easun Power
Easun Power IGRID-VX-IV-5.6KW-WIFI vs Easun Power ISolar SMG II 5.6KW
5 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.