Easun Power 6.2KW vs Easun Power POW-HVM6.2K-PRO (6.2KW)
VS
The verdict
6.2KW leads on the differences that matter
The largest is max pv power: 0.50 kW apart. 11 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
11
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 18 parameters
What actually differs
Parameter
6.2KW
POW-HVM6.2K-PRO (6.2KW)
Difference
Max PV power
6.50 kW
6.00 kW
0.50 kW apart
Weight
8.9 kg
10.3 kg
1.4 kg lighter
DC/AC ratio
1.05
0.97
0.08 more oversizing headroom
Weight per kW
1.4 kg/kW
1.7 kg/kW
0.2 kg/kW lighter
MPPT voltage range
60-500 V
60-450 V
60-500 V vs 60-450 V
Battery voltage
24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW)
48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) vs 48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
Dimensions
442x358x116 mm
449x324x136 mm
442x358x116 mm vs 449x324x136 mm
02
Full specification
Parameter
6.2KW
POW-HVM6.2K-PRO (6.2KW)
Difference
AC output
Rated AC power
6.20 kW
6.20 kW
Same
Max AC power
6.20 kW
6.20 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
26.9 A
-
Not published by Easun Power
PV input
Max PV power
6.50 kW
6.00 kW
0.50 kW apart
DC/AC ratio
1.05
0.97
+0.08 for 6.2KW
Max DC voltage
500 V
500 V
Same
MPPT voltage range
60-500 V
60-450 V
60-500 V vs 60-450 V
Start voltage
-
60 V
Not published by Easun Power
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
-
27.0 A
Not published by Easun Power
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
93.0 %
93.0 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW)
48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) vs 48 Vdc nominal (cold start 46 Vdc; low cut-off 42-43 Vdc; high cut-off 63 Vdc)
Max charge current
120 A
120 A
Same
Backup power
-
6.2 kW
Not published by Easun Power
Physical
Weight
8.9 kg
10.3 kg
-1.4 kg for 6.2KW
Weight per kW
1.4 kg/kW
1.7 kg/kW
-0.2 kg/kW for 6.2KW
Dimensions
442x358x116 mm
449x324x136 mm
442x358x116 mm vs 449x324x136 mm
Ingress protection
-
-
Neither datasheet publishes this
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
50 °C
50 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
Yes
Not published by Easun Power
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Easun Power
Easun Power 6.2KW vs Easun Power 6.2KVA (PVmax=500V, 48V battery)
4 differences, the largest is max efficiency
Same type, similar size
Easun Power
Easun Power 6.2KW vs Easun Power POW-HVM6200W-48V
3 differences, the largest is max efficiency
Same type, similar size
Easun Power
Easun Power 6.2KW vs Easun Power 6.2KVA (48V)
4 differences, the largest is max efficiency
Same type, similar size
Easun Power
Easun Power POW-HVM6.2K-PRO (6.2KW) vs Easun Power POW-HVM6.2KP
6 differences, the largest is max efficiency
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.
