Skip to main content
2KW vs 2KVA (48V) 12 of 16 identical Swap Change inverters

Easun Power 6.2KW vs Easun Power 6.2KVA (48V)

Easun Power 6.2KW
Easun Power
6.2KW
6.2 kW Hybrid
VS
Easun Power 6.2KVA (48V)
Easun Power
6.2KVA (48V)
6.2 kW Hybrid
The verdict

2KVA (48V) leads on the differences that matter

The largest is max efficiency: 1.0 pp more efficient. 12 of 16 comparable parameters are identical, with 16 more left out because at least one datasheet does not publish them.

See all 4 differences
How alike are they
12 of 16 comparable
parameters are identical
identical differs not published
01

What actually differs

4 of 16 parameters
Parameter 2KW 2KVA (48V) Difference
Max efficiency 93.0 % 94.0 % 1.0 pp more efficient
Weight 8.9 kg 10.0 kg 1.1 kg lighter
Max operating temperature 50 °C 55 °C 5 °C more heat tolerant
Battery voltage 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) 48 V nominal (charge settings 48.0-62.0 V; MPPT range depends on PV) 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) vs 48 V nominal (charge settings 48.0-62.0 V; MPPT range depends on PV)
02

Full specification

Parameter 2KW 2KVA (48V) Difference
AC output
Rated AC power 6.20 kW 6.20 kW Same
Max AC power 6.20 kW 6.20 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 26.9 A - Not published by Easun Power
PV input
Max PV power 6.50 kW 6.50 kW Same
DC/AC ratio 1.05 1.05 Same
Max DC voltage 500 V 500 V Same
MPPT voltage range 60-500 V 60-500 V Same
Start voltage - - Neither datasheet publishes this
MPP trackers - 1 Not published by Easun Power
Strings per tracker - - Neither datasheet publishes this
Max input current per tracker - 27.0 A Not published by Easun Power
Efficiency
European efficiency - - Neither datasheet publishes this
Max efficiency 93.0 % 94.0 % +1.0 pp for 2KVA (48V)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) 48 V nominal (charge settings 48.0-62.0 V; MPPT range depends on PV) 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) vs 48 V nominal (charge settings 48.0-62.0 V; MPPT range depends on PV)
Max charge current 120 A 120 A Same
Backup power - 6.2 kW Not published by Easun Power
Physical
Weight 8.9 kg 10.0 kg -1.1 kg for 2KW
Weight per kW 1.4 kg/kW 1.6 kg/kW Effectively the same
Dimensions 442x358x116 mm - Not published by Easun Power
Ingress protection - IP21 Not published by Easun Power
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 50 °C 55 °C +5 °C for 2KVA (48V)
Connectivity and safety
Wi-Fi Yes - Not published by Easun Power
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch - - Neither datasheet publishes this
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Easun Power
Easun Power 6.2KW vs Easun Power 6.2KVA (PVmax=500V, 48V battery)
4 differences, the largest is max efficiency
Same type, similar size
Easun Power
Easun Power 6.2KW vs Easun Power POW-HVM6200W-48V
3 differences, the largest is max efficiency
Same type, similar size
Easun Power
Easun Power 6.2KW vs Easun Power POW-HVM6.2K-PRO (6.2KW)
7 differences, the largest is max pv power
Same type, similar size
Easun Power
Easun Power 6.2KVA (48V) vs Easun Power POW-HVM6.2KP
6 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.