SUN2000-15KTL-M2 leads on the differences that matter
The largest is european efficiency: 0.5 pp more efficient. 10 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
10
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 24 parameters
What actually differs
Parameter
SUN-15K-G03-LV
SUN2000-15KTL-M2
Difference
European efficiency
97.8 %
98.3 %
0.5 pp more efficient
Max DC voltage
800 V
1080 V
280 V apart
Max input current per tracker
25.0 A
22.0 A
3.0 A more headroom
Max PV power
19.50 kW
22.50 kW
3.00 kW apart
Weight
28.0 kg
25.0 kg
3.0 kg lighter
DC/AC ratio
1.30
1.50
0.20 more oversizing headroom
Nominal AC voltage
220 V
400 V
180 V apart
Max AC current
43.3 A
25.2 A
18.1 A apart
Start voltage
250 V
200 V
50 V earlier start
Max operating temperature
65 °C
60 °C
5 °C more heat tolerant
MPPT voltage range
200-700 V
160-950 V
200-700 V vs 160-950 V
Weight per kW
1.9 kg/kW
1.7 kg/kW
0.2 kg/kW lighter
Dimensions
520x400x240 mm
470x525x262 mm
520x400x240 mm vs 470x525x262 mm
Cooling
forced-air
natural
forced-air vs natural
02
Full specification
Parameter
SUN-15K-G03-LV
SUN2000-15KTL-M2
Difference
AC output
Rated AC power
15.00 kW
15.00 kW
Same
Max AC power
16.50 kW
16.50 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
220 V
400 V
180 V apart
Max AC current
43.3 A
25.2 A
18.1 A apart
PV input
Max PV power
19.50 kW
22.50 kW
3.00 kW apart
DC/AC ratio
1.30
1.50
+0.20 for SUN2000-15KTL-M2
Max DC voltage
800 V
1080 V
280 V apart
MPPT voltage range
200-700 V
160-950 V
200-700 V vs 160-950 V
Start voltage
250 V
200 V
-50 V for SUN2000-15KTL-M2
MPP trackers
2
2
Same
Strings per tracker
2
2
Same
Max input current per tracker
25.0 A
22.0 A
+3.0 A for SUN-15K-G03-LV
Efficiency
European efficiency
97.8 %
98.3 %
+0.5 pp for SUN2000-15KTL-M2
Max efficiency
98.6 %
98.7 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
28.0 kg
25.0 kg
-3.0 kg for SUN2000-15KTL-M2
Weight per kW
1.9 kg/kW
1.7 kg/kW
-0.2 kg/kW for SUN2000-15KTL-M2
Dimensions
520x400x240 mm
470x525x262 mm
520x400x240 mm vs 470x525x262 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
natural
forced-air vs natural
Noise
45 dB
-
Not published by Huawei
Max operating temperature
65 °C
60 °C
+5 °C for SUN-15K-G03-LV
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
Yes
Not published by Deye
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Deye SUN-15K-G03-LV vs Growatt MID 15KTL3-X
12 differences, the largest is european efficiency
Same type, similar size
Sungrow
Deye SUN-15K-G03-LV vs Sungrow SG15KTL-M
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Deye SUN-15K-G03-LV vs Huawei SUN2000-15KTL-M0
12 differences, the largest is european efficiency
Same type, similar size
Growatt
Huawei SUN2000-15KTL-M2 vs Growatt MOD 15KTL3-X
9 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.