Deye SUN-110K-G03 vs Ginlong Solis S5-GC110K
VS
The verdict
SUN-110K-G03 leads on the differences that matter
The largest is max dc voltage: 100 V apart. 8 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
8
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 19 parameters
What actually differs
Parameter
SUN-110K-G03
S5-GC110K
Difference
Max DC voltage
1000 V
1100 V
100 V apart
Max input current per tracker
40.0 A
32.0 A
8.0 A more headroom
Weight
81.0 kg
91.0 kg
10.0 kg lighter
European efficiency
98.3 %
98.6 %
0.3 pp more efficient
Start voltage
250 V
195 V
55 V earlier start
Max operating temperature
65 °C
60 °C
5 °C more heat tolerant
Max efficiency
98.8 %
99.0 %
0.2 pp more efficient
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
200-850 V
180-1000 V
200-850 V vs 180-1000 V
Max AC current
183.3 A
183.8 A
0.5 A apart
Dimensions
568x838x346 mm
567x1065x344 mm
568x838x346 mm vs 567x1065x344 mm
02
Full specification
Parameter
SUN-110K-G03
S5-GC110K
Difference
AC output
Rated AC power
110.00 kW
110.00 kW
Same
Max AC power
121.00 kW
121.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
183.3 A
183.8 A
0.5 A apart
PV input
Max PV power
150.00 kW
-
Not published by Ginlong Solis
DC/AC ratio
1.36
-
Not published by Ginlong Solis
Max DC voltage
1000 V
1100 V
100 V apart
MPPT voltage range
200-850 V
180-1000 V
200-850 V vs 180-1000 V
Start voltage
250 V
195 V
-55 V for S5-GC110K
MPP trackers
-
10
Not published by Deye
Strings per tracker
-
2
Not published by Deye
Max input current per tracker
40.0 A
32.0 A
+8.0 A for SUN-110K-G03
Efficiency
European efficiency
98.3 %
98.6 %
+0.3 pp for S5-GC110K
Max efficiency
98.8 %
99.0 %
+0.2 pp for S5-GC110K
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
81.0 kg
91.0 kg
-10.0 kg for SUN-110K-G03
Weight per kW
0.7 kg/kW
0.8 kg/kW
Effectively the same
Dimensions
568x838x346 mm
567x1065x344 mm
568x838x346 mm vs 567x1065x344 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
forced-air
forced-air
Same
Noise
55 dB
-
Not published by Ginlong Solis
Max operating temperature
65 °C
60 °C
+5 °C for SUN-110K-G03
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
-
Yes
Not published by Deye
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Deye SUN-110K-G03 vs Solis-110K-HV-5G
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Deye SUN-110K-G03 vs Growatt MAX 110KTL3-X LV
10 differences, the largest is max dc voltage
Same type, similar size
SMA Solar
Deye SUN-110K-G03 vs SMA Solar Sunny Tripower CORE2 STP 110-60
13 differences, the largest is max dc voltage
Same type, similar size
Sofar Solar
Ginlong Solis S5-GC110K vs SOFAR 125KTLX-G4
7 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.