Skip to main content
SUN-110K-G03 vs S5-GC110K 8 of 19 identical Swap Change inverters

Deye SUN-110K-G03 vs Ginlong Solis S5-GC110K

Deye SUN-110K-G03
Deye
SUN-110K-G03
110 kW 98.3 % euro Grid-tie
VS
Ginlong Solis S5-GC110K
Ginlong Solis
S5-GC110K
110 kW 98.6 % euro Grid-tie
The verdict

SUN-110K-G03 leads on the differences that matter

The largest is max dc voltage: 100 V apart. 8 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
8 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 19 parameters
Parameter SUN-110K-G03 S5-GC110K Difference
Max DC voltage 1000 V 1100 V 100 V apart
Max input current per tracker 40.0 A 32.0 A 8.0 A more headroom
Weight 81.0 kg 91.0 kg 10.0 kg lighter
European efficiency 98.3 % 98.6 % 0.3 pp more efficient
Start voltage 250 V 195 V 55 V earlier start
Max operating temperature 65 °C 60 °C 5 °C more heat tolerant
Max efficiency 98.8 % 99.0 % 0.2 pp more efficient
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 200-850 V 180-1000 V 200-850 V vs 180-1000 V
Max AC current 183.3 A 183.8 A 0.5 A apart
Dimensions 568x838x346 mm 567x1065x344 mm 568x838x346 mm vs 567x1065x344 mm
02

Full specification

Parameter SUN-110K-G03 S5-GC110K Difference
AC output
Rated AC power 110.00 kW 110.00 kW Same
Max AC power 121.00 kW 121.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 183.3 A 183.8 A 0.5 A apart
PV input
Max PV power 150.00 kW - Not published by Ginlong Solis
DC/AC ratio 1.36 - Not published by Ginlong Solis
Max DC voltage 1000 V 1100 V 100 V apart
MPPT voltage range 200-850 V 180-1000 V 200-850 V vs 180-1000 V
Start voltage 250 V 195 V -55 V for S5-GC110K
MPP trackers - 10 Not published by Deye
Strings per tracker - 2 Not published by Deye
Max input current per tracker 40.0 A 32.0 A +8.0 A for SUN-110K-G03
Efficiency
European efficiency 98.3 % 98.6 % +0.3 pp for S5-GC110K
Max efficiency 98.8 % 99.0 % +0.2 pp for S5-GC110K
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 81.0 kg 91.0 kg -10.0 kg for SUN-110K-G03
Weight per kW 0.7 kg/kW 0.8 kg/kW Effectively the same
Dimensions 568x838x346 mm 567x1065x344 mm 568x838x346 mm vs 567x1065x344 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise 55 dB - Not published by Ginlong Solis
Max operating temperature 65 °C 60 °C +5 °C for SUN-110K-G03
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Ginlong Solis
Arc fault protection - Yes Not published by Deye
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Deye SUN-110K-G03 vs Solis-110K-HV-5G
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Deye SUN-110K-G03 vs Growatt MAX 110KTL3-X LV
10 differences, the largest is max dc voltage
Same type, similar size
SMA Solar
Deye SUN-110K-G03 vs SMA Solar Sunny Tripower CORE2 STP 110-60
13 differences, the largest is max dc voltage
Same type, similar size
Sofar Solar
Ginlong Solis S5-GC110K vs SOFAR 125KTLX-G4
7 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.