Skip to main content
stack (3 modules) vs 8.0 system (4 modules) 8 of 16 identical Swap Change batteries

Sigenergy SigenStor BAT stack (3 modules) vs Sigenergy SigenStor BAT 8.0 system (4 modules)

Sigenergy SigenStor BAT stack (3 modules)
SigenStor BAT stack (3 modules)
24.18 kWh LFP
VS
Sigenergy SigenStor BAT 8.0 system (4 modules)
SigenStor BAT 8.0 system (4 modules)
31.2 kWh LFP
The verdict

8.0 system (4 modules) leads on the differences that matter

The largest is usable energy: 7.02 kWh apart. 8 of 16 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.

See all 8 differences
How alike are they
8 of 16 comparable
parameters are identical
identical differs not published
01

What actually differs

8 of 16 parameters
Parameter stack (3 modules) 8.0 system (4 modules) Difference
Usable energy 24.18 kWh 31.20 kWh 7.02 kWh apart
Continuous discharge power 12.00 kW 16.00 kW 4.00 kW more power
Nominal energy 24.18 kWh 32.24 kWh 8.06 kWh apart
Continuous charge power 12.00 kW 16.00 kW 4.00 kW faster charging
Peak discharge power 18.00 kW 24.00 kW 6.00 kW more surge
Weight 237.0 kg 310.0 kg 73.0 kg lighter
Inverter None (battery only) Built in (all-in-one) None (battery only) vs Built in (all-in-one)
Dimensions 1180x850x260 mm 1450x850x260 mm 1180x850x260 mm vs 1450x850x260 mm

Shop prices by brand: See 15 Sigenergy offers

02

Full specification

Parameter stack (3 modules) 8.0 system (4 modules) Difference
Capacity
Usable energy 24.18 kWh 31.20 kWh 7.02 kWh apart
Nominal energy 24.18 kWh 32.24 kWh 8.06 kWh apart
Depth of discharge - - Neither datasheet publishes this
Max system capacity 48.4 kWh 48.4 kWh Same
Modules per stack 1-6 1-6 Same
Power
Continuous discharge power 12.00 kW 16.00 kW +4.00 kW for 8.0 system (4 modules)
Continuous charge power 12.00 kW 16.00 kW +4.00 kW for 8.0 system (4 modules)
Peak discharge power 18.00 kW 24.00 kW +6.00 kW for 8.0 system (4 modules)
Power per kWh 0.50 kW/kWh 0.51 kW/kWh Effectively the same
Efficiency and lifetime
Round-trip efficiency - - Neither datasheet publishes this
Cycle life - - Neither datasheet publishes this
Cycle test depth - - Neither datasheet publishes this
Capacity at end of life - - Neither datasheet publishes this
Self-discharge - - Neither datasheet publishes this
Electrical
Voltage class - - Neither datasheet publishes this
Nominal voltage - - Neither datasheet publishes this
Operating voltage - - Neither datasheet publishes this
Cell chemistry LFP LFP Same
Active cell balancing - - Neither datasheet publishes this
Thermal management - - Neither datasheet publishes this
Built-in inverter
Inverter None (battery only) Built in (all-in-one) None (battery only) vs Built in (all-in-one)
Inverter power - - Neither datasheet publishes this
Grid connection - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 237.0 kg 310.0 kg -73.0 kg for stack (3 modules)
Weight per kWh 9.8 kg/kWh 9.9 kg/kWh Effectively the same
Dimensions 1180x850x260 mm 1450x850x260 mm 1180x850x260 mm vs 1450x850x260 mm
Ingress protection IP66 IP66 Same
Outdoor-rated - - Neither datasheet publishes this
Min operating temperature -20 °C -20 °C Same
Max operating temperature 55 °C 55 °C Same
Warranty
Warranty - - Neither datasheet publishes this
Warranted throughput - - Neither datasheet publishes this
03

More useful comparisons

Open all batteries
Similar capacity
Sigenergy SigenStor BAT stack (3 modules) vs Sigenergy SigenStor BAT 8.0 system (3 modules)
3 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT stack (3 modules) vs Deye BOS-G25
8 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT stack (3 modules) vs Deye BOS-G25 Pro
12 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT 8.0 system (4 modules) vs Sigenergy SigenStor BAT stack (4 modules)
3 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT 8.0 system (4 modules) vs Sigenergy SigenStor BAT 8.0 system (5 modules)
7 differences, the largest is usable energy
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.