Sigenergy SigenStor BAT 5.0 vs BYD Battery-Box Premium HVS 5.1
VS
The verdict
15 differences, and they point both ways
The largest is continuous discharge power: 2.62 kW more power. 4 of 19 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 19 parameters
What actually differs
Parameter
SigenStor BAT 5.0
Battery-Box Premium HVS 5.1
Difference
Continuous discharge power
2.50 kW
5.12 kW
2.62 kW more power
Max system capacity
48.4 kWh
12.8 kWh
35.6 kWh more room to expand
Usable energy
5.20 kWh
5.12 kWh
0.08 kWh apart
Nominal energy
5.38 kWh
5.12 kWh
0.26 kWh apart
Continuous charge power
2.50 kW
5.12 kW
2.62 kW faster charging
Peak discharge power
3.75 kW
10.24 kW
6.49 kW more surge
Power per kWh
0.48 kW/kWh
1.00 kW/kWh
0.52 kW/kWh more power for its size
Weight
57.0 kg
91.0 kg
34.0 kg lighter
Weight per kWh
11.0 kg/kWh
17.8 kg/kWh
6.8 kg/kWh lighter
Min operating temperature
-20 °C
-10 °C
10 °C more cold tolerant
Max operating temperature
55 °C
50 °C
5 °C more heat tolerant
Ingress protection
IP66
IP55
IP66 vs IP55
Modules per stack
1-6
2-5
1-6 vs 2-5
Operating voltage
300-600 V
160-240 V
300-600 V vs 160-240 V
Dimensions
270x767x260 mm
762x585x298 mm
270x767x260 mm vs 762x585x298 mm
02
3 shops we track
Price offers
Shop
SigenStor BAT 5.0
Battery-Box Premium HVS 5.1
At this shop
All 1 offer for SigenStor BAT 5.0 · All 3 offers for Battery-Box Premium HVS 5.1
Shop prices by brand: See 15 Sigenergy offers · See 121 BYD offers
03
Full specification
Parameter
SigenStor BAT 5.0
Battery-Box Premium HVS 5.1
Difference
Capacity
Usable energy
5.20 kWh
5.12 kWh
0.08 kWh apart
Nominal energy
5.38 kWh
5.12 kWh
0.26 kWh apart
Depth of discharge
-
100 %
Not published by Sigenergy
Max system capacity
48.4 kWh
12.8 kWh
+35.6 kWh for SigenStor BAT 5.0
Modules per stack
1-6
2-5
1-6 vs 2-5
Power
Continuous discharge power
2.50 kW
5.12 kW
+2.62 kW for Battery-Box Premium HVS 5.1
Continuous charge power
2.50 kW
5.12 kW
+2.62 kW for Battery-Box Premium HVS 5.1
Peak discharge power
3.75 kW
10.24 kW
+6.49 kW for Battery-Box Premium HVS 5.1
Power per kWh
0.48 kW/kWh
1.00 kW/kWh
+0.52 kW/kWh for Battery-Box Premium HVS 5.1
Efficiency and lifetime
Round-trip efficiency
-
96.0 %
Not published by Sigenergy
Cycle life
-
-
Neither datasheet publishes this
Cycle test depth
100 %
100 %
Same
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
-
205 V
Not published by Sigenergy
Operating voltage
300-600 V
160-240 V
300-600 V vs 160-240 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
57.0 kg
91.0 kg
-34.0 kg for SigenStor BAT 5.0
Weight per kWh
11.0 kg/kWh
17.8 kg/kWh
-6.8 kg/kWh for SigenStor BAT 5.0
Dimensions
270x767x260 mm
762x585x298 mm
270x767x260 mm vs 762x585x298 mm
Ingress protection
IP66
IP55
IP66 vs IP55
Outdoor-rated
-
Yes
Not published by Sigenergy
Min operating temperature
-20 °C
-10 °C
-10 °C for SigenStor BAT 5.0
Max operating temperature
55 °C
50 °C
+5 °C for SigenStor BAT 5.0
Warranty
Warranty
-
10 yrs
Not published by Sigenergy
Warranted throughput
-
-
Neither datasheet publishes this
04
Open all batteries
More useful comparisons
Similar capacity
Sigenergy SigenStor BAT 5.0 vs FoxESS ECS2900-H2
9 differences, the largest is max system capacity
Similar capacity
Sigenergy SigenStor BAT 5.0 vs Huawei LUNA2000-5-S0
9 differences, the largest is usable energy
Similar capacity
Sigenergy SigenStor BAT 5.0 vs GoodWe Lynx D LX D5.0-10
11 differences, the largest is usable energy
05
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.