Deye RW-L10.2 vs Deye SE-F12
VS
The verdict
SE-F12 leads on the differences that matter
The largest is usable energy: 0.38 kWh apart. 4 of 13 comparable parameters are identical, with 20 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
4
of 13 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 13 parameters
What actually differs
Parameter
RW-L10.2
SE-F12
Difference
Usable energy
10.24 kWh
10.62 kWh
0.38 kWh apart
Max system capacity
327.7 kWh
339.8 kWh
12.2 kWh more room to expand
Continuous discharge power
12.00 kW
11.78 kW
0.22 kW more power
Nominal energy
10.24 kWh
11.80 kWh
1.56 kWh apart
Weight
98.0 kg
82.0 kg
16.0 kg lighter
Weight per kWh
9.6 kg/kWh
7.7 kg/kWh
1.8 kg/kWh lighter
Ingress protection
IP65
IP21
IP65 vs IP21
Power per kWh
1.17 kW/kWh
1.11 kW/kWh
0.06 kW/kWh more power for its size
Dimensions
745x745x170 mm
232x400x232 mm
745x745x170 mm vs 232x400x232 mm
02
6 shops we track
Price offers
Shop
RW-L10.2
SE-F12
At this shop
Shop prices by brand: See 44 Deye offers
03
Full specification
Parameter
RW-L10.2
SE-F12
Difference
Capacity
Usable energy
10.24 kWh
10.62 kWh
0.38 kWh apart
Nominal energy
10.24 kWh
11.80 kWh
1.56 kWh apart
Depth of discharge
-
90 %
Not published by Deye
Max system capacity
327.7 kWh
339.8 kWh
+12.2 kWh for SE-F12
Modules per stack
-
-
Neither datasheet publishes this
Power
Continuous discharge power
12.00 kW
11.78 kW
+0.22 kW for RW-L10.2
Continuous charge power
-
11.78 kW
Not published by Deye
Peak discharge power
-
14.34 kW
Not published by Deye
Power per kWh
1.17 kW/kWh
1.11 kW/kWh
+0.06 kW/kWh for RW-L10.2
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
-
6000 cycles
Not published by Deye
Cycle test depth
-
-
Neither datasheet publishes this
Capacity at end of life
-
70 %
Not published by Deye
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
Low voltage
Low voltage
Same
Nominal voltage
51 V
51 V
Same
Operating voltage
-
44.8-57.6 V
Not published by Deye
Cell chemistry
-
LFP
Not published by Deye
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
98.0 kg
82.0 kg
-16.0 kg for SE-F12
Weight per kWh
9.6 kg/kWh
7.7 kg/kWh
-1.8 kg/kWh for SE-F12
Dimensions
745x745x170 mm
232x400x232 mm
745x745x170 mm vs 232x400x232 mm
Ingress protection
IP65
IP21
IP65 vs IP21
Outdoor-rated
-
-
Neither datasheet publishes this
Min operating temperature
-
-20 °C
Not published by Deye
Max operating temperature
55 °C
55 °C
Same
Warranty
Warranty
10 yrs
-
Not published by Deye
Warranted throughput
-
-
Neither datasheet publishes this
04
Open all batteries
More useful comparisons
Similar capacity
Deye RW-L10.2 vs Deye SE-G 10.2
7 differences, the largest is continuous discharge power
Similar capacity
Deye RW-L10.2 vs FelicityESS LUX-E-48200LG03
7 differences, the largest is usable energy
Similar capacity
Deye RW-L10.2 vs Deye RW-G10.6
7 differences, the largest is usable energy
Similar capacity
Deye SE-F12 vs FelicityESS LUX-E-48230LG03
6 differences, the largest is usable energy
05
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.