Deye GB-L8 vs Sigenergy SigenStor BAT 8.0
VS
The verdict
GB-L8 leads on the differences that matter
The largest is usable energy: 0.44 kWh apart. 3 of 18 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
3
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 18 parameters
What actually differs
Parameter
GB-L8
SigenStor BAT 8.0
Difference
Usable energy
7.36 kWh
7.80 kWh
0.44 kWh apart
Continuous discharge power
8.19 kW
4.00 kW
4.19 kW more power
Max system capacity
24.5 kWh
48.4 kWh
23.8 kWh more room to expand
Continuous charge power
8.19 kW
4.00 kW
4.19 kW faster charging
Peak discharge power
10.24 kW
6.00 kW
4.24 kW more surge
Power per kWh
1.11 kW/kWh
0.51 kW/kWh
0.60 kW/kWh more power for its size
Weight
97.0 kg
73.0 kg
24.0 kg lighter
Weight per kWh
13.2 kg/kWh
9.4 kg/kWh
3.8 kg/kWh lighter
Nominal energy
8.18 kWh
8.06 kWh
0.12 kWh apart
Max operating temperature
60 °C
55 °C
5 °C more heat tolerant
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Ingress protection
IP65
IP66
IP65 vs IP66
Modules per stack
2-6
1-6
2-6 vs 1-6
Operating voltage
166.4-700 V
300-600 V
166.4-700 V vs 300-600 V
Dimensions
650x540x385 mm
270x767x260 mm
650x540x385 mm vs 270x767x260 mm
02
1 shop we track
Price offers
Shop
GB-L8
SigenStor BAT 8.0
At this shop
Shop prices by brand: See 44 Deye offers · See 15 Sigenergy offers
03
Full specification
Parameter
GB-L8
SigenStor BAT 8.0
Difference
Capacity
Usable energy
7.36 kWh
7.80 kWh
0.44 kWh apart
Nominal energy
8.18 kWh
8.06 kWh
0.12 kWh apart
Depth of discharge
90 %
-
Not published by Sigenergy
Max system capacity
24.5 kWh
48.4 kWh
+23.8 kWh for SigenStor BAT 8.0
Modules per stack
2-6
1-6
2-6 vs 1-6
Power
Continuous discharge power
8.19 kW
4.00 kW
+4.19 kW for GB-L8
Continuous charge power
8.19 kW
4.00 kW
+4.19 kW for GB-L8
Peak discharge power
10.24 kW
6.00 kW
+4.24 kW for GB-L8
Power per kWh
1.11 kW/kWh
0.51 kW/kWh
+0.60 kW/kWh for GB-L8
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
6000 cycles
-
Not published by Sigenergy
Cycle test depth
-
100 %
Not published by Deye
Capacity at end of life
70 %
-
Not published by Sigenergy
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
205 V
-
Not published by Sigenergy
Operating voltage
166.4-700 V
300-600 V
166.4-700 V vs 300-600 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
Yes
-
Not published by Sigenergy
Built-in inverter
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
97.0 kg
73.0 kg
-24.0 kg for SigenStor BAT 8.0
Weight per kWh
13.2 kg/kWh
9.4 kg/kWh
-3.8 kg/kWh for SigenStor BAT 8.0
Dimensions
650x540x385 mm
270x767x260 mm
650x540x385 mm vs 270x767x260 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Outdoor-rated
Yes
-
Not published by Sigenergy
Min operating temperature
-20 °C
-20 °C
Same
Max operating temperature
60 °C
55 °C
+5 °C for GB-L8
Warranty
Warranty
10 yrs
-
Not published by Sigenergy
Warranted throughput
-
-
Neither datasheet publishes this
04
Open all batteries
More useful comparisons
Similar capacity
Deye GB-L8 vs Deye GB-SL-EU (2 modules in series)
5 differences, the largest is weight
Similar capacity
Deye GB-L8 vs Dyness Tower Pro TP7
16 differences, the largest is continuous discharge power
Similar capacity
Deye GB-L8 vs FoxESS ECS4300H-H2
10 differences, the largest is max system capacity
Similar capacity
Sigenergy SigenStor BAT 8.0 vs FoxESS ECS2900-H3
10 differences, the largest is max system capacity
Similar capacity
Sigenergy SigenStor BAT 8.0 vs BYD Battery-Box Premium HVS 7.7
16 differences, the largest is continuous discharge power
05
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.