FoxESS HS12.5 vs FoxESS ECS4300H-H3
VS
The verdict
ECS4300H-H3 leads on the differences that matter
The largest is usable energy: 0.71 kWh apart. 5 of 14 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
5
of 14 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 14 parameters
What actually differs
Parameter
HS12.5
ECS4300H-H3
Difference
Usable energy
11.91 kWh
11.20 kWh
0.71 kWh apart
Max system capacity
19.6 kWh
29.0 kWh
9.4 kWh more room to expand
Nominal voltage
256 V
173 V
83 V apart
Min operating temperature
-10 °C
-20 °C
10 °C more cold tolerant
Nominal energy
12.28 kWh
12.44 kWh
0.16 kWh apart
Cycle test depth
80 %
90 %
10 pp apart
Ingress protection
IP21
IP65
IP21 vs IP65
Modules per stack
2-8
2-7
2-8 vs 2-7
Operating voltage
216-292 V
145.8-197.1 V
216-292 V vs 145.8-197.1 V
Shop prices by brand: See 21 FoxESS offers
02
Full specification
Parameter
HS12.5
ECS4300H-H3
Difference
Capacity
Usable energy
11.91 kWh
11.20 kWh
0.71 kWh apart
Nominal energy
12.28 kWh
12.44 kWh
0.16 kWh apart
Depth of discharge
-
90 %
Not published by FoxESS
Max system capacity
19.6 kWh
29.0 kWh
+9.4 kWh for ECS4300H-H3
Modules per stack
2-8
2-7
2-8 vs 2-7
Power
Continuous discharge power
-
-
Neither datasheet publishes this
Continuous charge power
-
-
Neither datasheet publishes this
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
-
-
Neither datasheet publishes this
Efficiency and lifetime
Round-trip efficiency
-
95.0 %
Not published by FoxESS
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
80 %
90 %
10 pp apart
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
256 V
173 V
83 V apart
Operating voltage
216-292 V
145.8-197.1 V
216-292 V vs 145.8-197.1 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
-
115.5 kg
Not published by FoxESS
Weight per kWh
-
10.3 kg/kWh
Not published by FoxESS
Dimensions
-
494x570x380 mm
Not published by FoxESS
Ingress protection
IP21
IP65
IP21 vs IP65
Outdoor-rated
-
Yes
Not published by FoxESS
Min operating temperature
-10 °C
-20 °C
-10 °C for ECS4300H-H3
Max operating temperature
55 °C
55 °C
Same
Warranty
Warranty
10 yrs
-
Not published by FoxESS
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
FoxESS HS12.5 vs Solplanet Ai-HB 125A
8 differences, the largest is usable energy
Similar capacity
FoxESS HS12.5 vs Pylontech Force H1 (5 modules)
7 differences, the largest is usable energy
Similar capacity
FoxESS HS12.5 vs BYD Battery-Box Premium HVM 11.0
6 differences, the largest is usable energy
Similar capacity
FoxESS ECS4300H-H3 vs Deye GB-L12
10 differences, the largest is usable energy
Similar capacity
FoxESS ECS4300H-H3 vs Deye GB-SL-EU (3 modules in series)
11 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.
