FoxESS ECS2900-H7 vs Dyness Tower T17
VS
The verdict
ECS2900-H7 leads on the differences that matter
The largest is usable energy: 0.38 kWh apart. 5 of 14 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
5
of 14 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 14 parameters
What actually differs
Parameter
ECS2900-H7
Tower T17
Difference
Usable energy
18.14 kWh
17.76 kWh
0.38 kWh apart
Nominal energy
20.16 kWh
17.76 kWh
2.40 kWh apart
Depth of discharge
90 %
100 %
10 pp more of the cells usable
Nominal voltage
403 V
480 V
77 V apart
Min operating temperature
-20 °C
-10 °C
10 °C more cold tolerant
Max operating temperature
55 °C
50 °C
5 °C more heat tolerant
Ingress protection
IP65
IP54
IP65 vs IP54
Modules per stack
2-7
2-6
2-7 vs 2-6
Dimensions
950x570x380 mm
1300x504x380 mm
950x570x380 mm vs 1300x504x380 mm
Shop prices by brand: See 21 FoxESS offers · See 20 Dyness offers
02
Full specification
Parameter
ECS2900-H7
Tower T17
Difference
Capacity
Usable energy
18.14 kWh
17.76 kWh
0.38 kWh apart
Nominal energy
20.16 kWh
17.76 kWh
2.40 kWh apart
Depth of discharge
90 %
100 %
+10 pp for Tower T17
Max system capacity
20.2 kWh
-
Not published by Dyness
Modules per stack
2-7
2-6
2-7 vs 2-6
Power
Continuous discharge power
-
10.65 kW
Not published by FoxESS
Continuous charge power
-
10.65 kW
Not published by FoxESS
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
-
0.60 kW/kWh
Not published by FoxESS
Efficiency and lifetime
Round-trip efficiency
95.0 %
-
Not published by Dyness
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
90 %
-
Not published by Dyness
Capacity at end of life
-
-
Neither datasheet publishes this
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
403 V
480 V
77 V apart
Operating voltage
340.2-459.9 V
-
Not published by Dyness
Cell chemistry
LFP
-
Not published by Dyness
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
None (battery only)
Same
Inverter power
-
-
Neither datasheet publishes this
Grid connection
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
228.3 kg
228.0 kg
Effectively the same
Weight per kWh
12.6 kg/kWh
12.8 kg/kWh
Effectively the same
Dimensions
950x570x380 mm
1300x504x380 mm
950x570x380 mm vs 1300x504x380 mm
Ingress protection
IP65
IP54
IP65 vs IP54
Outdoor-rated
Yes
-
Not published by Dyness
Min operating temperature
-20 °C
-10 °C
-10 °C for ECS2900-H7
Max operating temperature
55 °C
50 °C
+5 °C for ECS2900-H7
Warranty
Warranty
-
10 yrs
Not published by FoxESS
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
FoxESS ECS2900-H7 vs Dyness Tower Pro TP19
13 differences, the largest is cycle life
Similar capacity
FoxESS ECS2900-H7 vs Deye GB-L20
10 differences, the largest is usable energy
Similar capacity
FoxESS ECS2900-H7 vs Deye GB-SL-EU (5 modules in series)
11 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.