BOS-B (15 modules in series; system config shown)
vs
BC197DE
4 of 14 identical
Swap
Change batteries
Deye BOS-B (15 modules in series; system config shown) vs KSTAR BC197DE
BOS-B (15 modules in series; system config shown)
193.05 kWh
90.0 % round-trip
LFP HV
VS
The verdict
BOS-B (15 modules in series; system config shown) leads on the differences that matter
The largest is usable energy: 15.75 kWh apart. 4 of 14 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
4
of 14 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 14 parameters
What actually differs
Parameter
BOS-B (15 modules in series; system config shown)
BC197DE
Difference
Usable energy
193.05 kWh
177.30 kWh
15.75 kWh apart
Nominal energy
214.50 kWh
197.00 kWh
17.50 kWh apart
Nominal voltage
720 V
704 V
16 V apart
Weight
1850.0 kg
2500.0 kg
650.0 kg lighter
Weight per kWh
9.6 kg/kWh
14.1 kg/kWh
4.5 kg/kWh lighter
Min operating temperature
-20 °C
-30 °C
10 °C more cold tolerant
Max operating temperature
55 °C
50 °C
5 °C more heat tolerant
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Ingress protection
IP20
IP54 (battery cabinet); IP65 (inverter)
IP20 vs IP54 (battery cabinet); IP65 (inverter)
Dimensions
1136x2150x800 mm
2380x1300x1200 mm
1136x2150x800 mm vs 2380x1300x1200 mm
Shop prices by brand: See 44 Deye offers
02
Full specification
Parameter
BOS-B (15 modules in series; system config shown)
BC197DE
Difference
Capacity
Usable energy
193.05 kWh
177.30 kWh
15.75 kWh apart
Nominal energy
214.50 kWh
197.00 kWh
17.50 kWh apart
Depth of discharge
90 %
90 %
Same
Max system capacity
214.5 kWh
-
Not published by KSTAR
Modules per stack
5-15
-
Not published by KSTAR
Power
Continuous discharge power
-
-
Neither datasheet publishes this
Continuous charge power
-
-
Neither datasheet publishes this
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
-
-
Neither datasheet publishes this
Efficiency and lifetime
Round-trip efficiency
90.0 %
-
Not published by KSTAR
Cycle life
6000 cycles
-
Not published by KSTAR
Cycle test depth
90 %
-
Not published by KSTAR
Capacity at end of life
70 %
-
Not published by KSTAR
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
720 V
704 V
16 V apart
Operating voltage
-
616-792 V
Not published by Deye
Cell chemistry
LFP
LFP
Same
Active cell balancing
Yes
-
Not published by KSTAR
Thermal management
Yes
Yes
Same
Built-in inverter
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Inverter power
-
50.0 kW
Not published by Deye
Grid connection
-
3-phase
Not published by Deye
Backup power
-
50.0 kW
Not published by Deye
Physical
Weight
1850.0 kg
2500.0 kg
-650.0 kg for BOS-B (15 modules in series; system config shown)
Weight per kWh
9.6 kg/kWh
14.1 kg/kWh
-4.5 kg/kWh for BOS-B (15 modules in series; system config shown)
Dimensions
1136x2150x800 mm
2380x1300x1200 mm
1136x2150x800 mm vs 2380x1300x1200 mm
Ingress protection
IP20
IP54 (battery cabinet); IP65 (inverter)
IP20 vs IP54 (battery cabinet); IP65 (inverter)
Outdoor-rated
-
Yes
Not published by Deye
Min operating temperature
-20 °C
-30 °C
-10 °C for BC197DE
Max operating temperature
55 °C
50 °C
+5 °C for BOS-B (15 modules in series; system config shown)
Warranty
Warranty
10 yrs
-
Not published by KSTAR
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Deye BOS-B (15 modules in series; system config shown) vs Huawei LUNA2000-200KWH-2H1
9 differences, the largest is usable energy
Similar capacity
Deye BOS-B (15 modules in series; system config shown) vs Huawei LUNA2000-161KWH-2H1
9 differences, the largest is usable energy
Similar capacity
Deye BOS-B (15 modules in series; system config shown) vs Deye BOS-A (23 modules in series)
8 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.