Deye BOS-G60 vs Deye GE-F60-EU
VS
The verdict
9 differences, and they point both ways
The largest is usable energy: 6.11 kWh apart. 6 of 15 comparable parameters are identical, with 18 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
6
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 15 parameters
What actually differs
Parameter
BOS-G60
GE-F60-EU
Difference
Usable energy
55.29 kWh
61.40 kWh
6.11 kWh apart
Weight
610.0 kg
1095.0 kg
485.0 kg lighter
Weight per kWh
11.0 kg/kWh
17.8 kg/kWh
6.8 kg/kWh lighter
Min operating temperature
-20 °C
-40 °C
20 °C more cold tolerant
Max operating temperature
55 °C
60 °C
5 °C more heat tolerant
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Ingress protection
IP20
IP55
IP20 vs IP55
Operating voltage
499.2-700 V
500-700 V
499.2-700 V vs 500-700 V
Dimensions
2219x530x602 mm
2235x735x1045 mm
2219x530x602 mm vs 2235x735x1045 mm
Shop prices by brand: See 44 Deye offers
02
Full specification
Parameter
BOS-G60
GE-F60-EU
Difference
Capacity
Usable energy
55.29 kWh
61.40 kWh
6.11 kWh apart
Nominal energy
61.44 kWh
61.40 kWh
Effectively the same
Depth of discharge
90 %
-
Not published by Deye
Max system capacity
61.4 kWh
-
Not published by Deye
Modules per stack
3-12
-
Not published by Deye
Power
Continuous discharge power
-
50.00 kW
Not published by Deye
Continuous charge power
-
-
Neither datasheet publishes this
Peak discharge power
-
75.00 kW
Not published by Deye
Power per kWh
-
0.81 kW/kWh
Not published by Deye
Efficiency and lifetime
Round-trip efficiency
-
91.0 %
Not published by Deye
Cycle life
6000 cycles
6000 cycles
Same
Cycle test depth
90 %
-
Not published by Deye
Capacity at end of life
70 %
70 %
Same
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
614 V
-
Not published by Deye
Operating voltage
499.2-700 V
500-700 V
499.2-700 V vs 500-700 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
-
Neither datasheet publishes this
Built-in inverter
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Inverter power
-
50.0 kW
Not published by Deye
Grid connection
-
3-phase
Not published by Deye
Backup power
-
50.0 kW
Not published by Deye
Physical
Weight
610.0 kg
1095.0 kg
-485.0 kg for BOS-G60
Weight per kWh
11.0 kg/kWh
17.8 kg/kWh
-6.8 kg/kWh for BOS-G60
Dimensions
2219x530x602 mm
2235x735x1045 mm
2219x530x602 mm vs 2235x735x1045 mm
Ingress protection
IP20
IP55
IP20 vs IP55
Outdoor-rated
-
-
Neither datasheet publishes this
Min operating temperature
-20 °C
-40 °C
-20 °C for GE-F60-EU
Max operating temperature
55 °C
60 °C
+5 °C for GE-F60-EU
Warranty
Warranty
10 yrs
10 yrs
Same
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Deye BOS-G60 vs Deye BOS-G60 Pro
5 differences, the largest is max system capacity
Similar capacity
Deye BOS-G60 vs Deye BOS-G55
5 differences, the largest is usable energy
Similar capacity
Deye BOS-G60 vs Deye BOS-A (7 modules in series)
8 differences, the largest is usable energy
Similar capacity
Deye GE-F60-EU vs Deye BOS-G80 Pro
13 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.