VS
The verdict
BOS-A (23 modules in series) leads on the differences that matter
The largest is usable energy: 18.32 kWh apart. 3 of 14 comparable parameters are identical, with 19 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
3
of 14 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 14 parameters
What actually differs
Parameter
BOS-A (23 modules in series)
BC197DE
Difference
Usable energy
158.98 kWh
177.30 kWh
18.32 kWh apart
Nominal energy
176.64 kWh
197.00 kWh
20.36 kWh apart
Nominal voltage
883 V
704 V
179 V apart
Weight
1710.0 kg
2500.0 kg
790.0 kg lighter
Weight per kWh
10.8 kg/kWh
14.1 kg/kWh
3.3 kg/kWh lighter
Min operating temperature
-20 °C
-30 °C
10 °C more cold tolerant
Max operating temperature
55 °C
50 °C
5 °C more heat tolerant
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Ingress protection
IP20
IP54 (battery cabinet); IP65 (inverter)
IP20 vs IP54 (battery cabinet); IP65 (inverter)
Operating voltage
745.2-993.6 V
616-792 V
745.2-993.6 V vs 616-792 V
Dimensions
1921x1258x605 mm
2380x1300x1200 mm
1921x1258x605 mm vs 2380x1300x1200 mm
Shop prices by brand: See 44 Deye offers
02
Full specification
Parameter
BOS-A (23 modules in series)
BC197DE
Difference
Capacity
Usable energy
158.98 kWh
177.30 kWh
18.32 kWh apart
Nominal energy
176.64 kWh
197.00 kWh
20.36 kWh apart
Depth of discharge
90 %
90 %
Same
Max system capacity
176.6 kWh
-
Not published by KSTAR
Modules per stack
7-23
-
Not published by KSTAR
Power
Continuous discharge power
-
-
Neither datasheet publishes this
Continuous charge power
-
-
Neither datasheet publishes this
Peak discharge power
-
-
Neither datasheet publishes this
Power per kWh
-
-
Neither datasheet publishes this
Efficiency and lifetime
Round-trip efficiency
-
-
Neither datasheet publishes this
Cycle life
6000 cycles
-
Not published by KSTAR
Cycle test depth
90 %
-
Not published by KSTAR
Capacity at end of life
70 %
-
Not published by KSTAR
Self-discharge
-
-
Neither datasheet publishes this
Electrical
Voltage class
High voltage
High voltage
Same
Nominal voltage
883 V
704 V
179 V apart
Operating voltage
745.2-993.6 V
616-792 V
745.2-993.6 V vs 616-792 V
Cell chemistry
LFP
LFP
Same
Active cell balancing
-
-
Neither datasheet publishes this
Thermal management
-
Yes
Not published by Deye
Built-in inverter
Inverter
None (battery only)
Built in (all-in-one)
None (battery only) vs Built in (all-in-one)
Inverter power
-
50.0 kW
Not published by Deye
Grid connection
-
3-phase
Not published by Deye
Backup power
-
50.0 kW
Not published by Deye
Physical
Weight
1710.0 kg
2500.0 kg
-790.0 kg for BOS-A (23 modules in series)
Weight per kWh
10.8 kg/kWh
14.1 kg/kWh
-3.3 kg/kWh for BOS-A (23 modules in series)
Dimensions
1921x1258x605 mm
2380x1300x1200 mm
1921x1258x605 mm vs 2380x1300x1200 mm
Ingress protection
IP20
IP54 (battery cabinet); IP65 (inverter)
IP20 vs IP54 (battery cabinet); IP65 (inverter)
Outdoor-rated
-
Yes
Not published by Deye
Min operating temperature
-20 °C
-30 °C
-10 °C for BC197DE
Max operating temperature
55 °C
50 °C
+5 °C for BOS-A (23 modules in series)
Warranty
Warranty
10 yrs
-
Not published by KSTAR
Warranted throughput
-
-
Neither datasheet publishes this
03
Open all batteries
More useful comparisons
Similar capacity
Deye BOS-A (23 modules in series) vs GoodWe LX C156-10
10 differences, the largest is usable energy
Similar capacity
Deye BOS-A (23 modules in series) vs Huawei LUNA2000-161KWH-2H1
10 differences, the largest is usable energy
Similar capacity
Deye BOS-A (23 modules in series) vs GoodWe LX C138-10
10 differences, the largest is usable energy
Similar capacity
KSTAR BC197DE vs Deye BOS-B (15 modules in series; system config shown)
10 differences, the largest is usable energy
Similar capacity
KSTAR BC197DE vs Huawei LUNA2000-200KWH-2H1
9 differences, the largest is usable energy
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.