Skip to main content
VSUN460N-120BMH-DG-BB vs VSUN475N-120BMH-DG-BB 16 of 19 identical Swap Change panels

VSUN VSUN460N-120BMH-DG-BB vs VSUN VSUN475N-120BMH-DG-BB

VSUN
VSUN460N-120BMH-DG-BB
460 Wp 21.26 % TOPCon Bifacial
VS
VSUN
VSUN475N-120BMH-DG-BB
475 Wp 21.95 % TOPCon Bifacial
The verdict

VSUN475N-120BMH-DG-BB leads on the differences that matter

The largest is module efficiency: 0.69 pp more efficient. 16 of 19 comparable parameters are identical.

See all 3 differences
How alike are they
16 of 19 comparable
parameters are identical
identical differs
01

What actually differs

3 of 19 parameters
Parameter VSUN460N-120BMH-DG-BB VSUN475N-120BMH-DG-BB Difference
Module efficiency 21.26 % 21.95 % 0.69 pp more efficient
Power density 212.6 Wp/m² 219.5 Wp/m² 6.9 Wp/m² higher
Rated power 460 Wp 475 Wp 15 W more power
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.300 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
VSUN460N-120BMH-DG-BB
15,434 kWh
VSUN475N-120BMH-DG-BB
15,937 kWh
Lifetime gap
503 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario VSUN460N-120BMH-DG-BB VSUN475N-120BMH-DG-BB
Standard test conditions 25 °C 100.0% of rated power 460 W 475 W
Cool, bright day 40 °C 95.5% of rated power 439 W 454 W
Typical summer roof 55 °C 91.0% of rated power 419 W 432 W
Hot roof 70 °C 86.5% of rated power 398 W 411 W
03

Full specification

Parameter VSUN460N-120BMH-DG-BB VSUN475N-120BMH-DG-BB Difference
Power and efficiency
Rated power 460 Wp 475 Wp +15 W for VSUN475N-120BMH-DG-BB
Module efficiency 21.26 % 21.95 % +0.69 pp for VSUN475N-120BMH-DG-BB
Power density 212.6 Wp/m² 219.5 Wp/m² +6.9 Wp/m² for VSUN475N-120BMH-DG-BB
Open-circuit voltage 42.07 V 42.53 V Effectively the same
Voltage at max power 34.76 V 35.23 V Effectively the same
Short-circuit current 13.99 A 14.23 A Effectively the same
Current at max power 13.24 A 13.49 A Effectively the same
Temperature
Temperature coefficient -0.300 %/°C -0.300 %/°C Same
Mechanical
Dimensions 1908x1134x30 mm 1908x1134x30 mm Same
Module area 2.164 m² 2.164 m² Same
Weight 26.7 kg 26.7 kg Same
Weight per kWp 58.0 kg/kWp 56.2 kg/kWp Effectively the same
Warranty and degradation
Product warranty 25 yrs 25 yrs Same
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 120 120 Same
Bifacial Yes Yes Same
04

Against the whole database

14,005 panels
Efficiency
#8,894 vs #6,745
VSUN475N-120BMH-DG-BB leads by 2,149 places
Power density
#8,778 vs #6,702
VSUN475N-120BMH-DG-BB leads by 2,076 places
Heat behaviour
#6,093 vs #6,093
Tied - the same position in the database
Weight
#11,546 vs #10,496
VSUN475N-120BMH-DG-BB leads by 1,050 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#7,480 vs #6,005
VSUN475N-120BMH-DG-BB leads by 1,475 places
05

More useful comparisons

Open the full database
Same series, other bin
VSUN
VSUN VSUN460N-120BMH-DG-BB vs VSUN VSUN470N-120BMH-DG-BB
3 differences, the largest is module efficiency
Same series, other bin
VSUN
VSUN VSUN460N-120BMH-DG-BB vs VSUN VSUN465N-120BMH-DG-BB
One difference: module efficiency
Same manufacturer
VSUN
VSUN VSUN460N-120BMH-DG-BB vs VSUN VSUN715N-132BMHT-DG
13 differences, the largest is module efficiency
Same manufacturer
VSUN
VSUN VSUN460N-120BMH-DG-BB vs VSUN VSUN710N-132BMHT-DG
13 differences, the largest is module efficiency
Same manufacturer
VSUN
VSUN VSUN460N-120BMH-DG-BB vs VSUN VSUN705N-132BMHT-DG
13 differences, the largest is module efficiency
Same manufacturer
VSUN
VSUN VSUN460N-120BMH-DG-BB vs VSUN VSUN700N-132BMH-DG
13 differences, the largest is module efficiency
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: VSUN VSUN460N-120BMH-DG-BB or VSUN VSUN475N-120BMH-DG-BB?
According to our database: VSUN VSUN475N-120BMH-DG-BB has higher module efficiency (21.95% vs 21.26%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of VSUN VSUN460N-120BMH-DG-BB and VSUN VSUN475N-120BMH-DG-BB?
VSUN VSUN460N-120BMH-DG-BB has a module efficiency of 21.26%, while VSUN VSUN475N-120BMH-DG-BB is 21.95%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does VSUN VSUN460N-120BMH-DG-BB use vs VSUN VSUN475N-120BMH-DG-BB?
VSUN VSUN460N-120BMH-DG-BB uses TOPCon cells; VSUN VSUN475N-120BMH-DG-BB uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on VSUN VSUN460N-120BMH-DG-BB and VSUN VSUN475N-120BMH-DG-BB?
VSUN VSUN460N-120BMH-DG-BB has a 30 years power warranty; VSUN VSUN475N-120BMH-DG-BB has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are VSUN VSUN460N-120BMH-DG-BB and VSUN VSUN475N-120BMH-DG-BB bifacial panels?
Both VSUN VSUN460N-120BMH-DG-BB and VSUN VSUN475N-120BMH-DG-BB are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 3 VSUN offers

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.