Skip to main content
VSUN420N-108BMH-DG-BB vs VSUN700N-132BMH-DG 6 of 19 identical Swap Change panels

VSUN VSUN420N-108BMH-DG-BB vs VSUN VSUN700N-132BMH-DG

VSUN
VSUN420N-108BMH-DG-BB
420 Wp 21.51 % TOPCon Bifacial
VS
VSUN
VSUN700N-132BMH-DG
700 Wp 22.53 % TOPCon Bifacial
The verdict

VSUN700N-132BMH-DG leads on the differences that matter

The largest is module efficiency: 1.02 pp more efficient. 6 of 19 comparable parameters are identical.

See all 13 differences
How alike are they
6 of 19 comparable
parameters are identical
identical differs
01

What actually differs

13 of 19 parameters
Parameter VSUN420N-108BMH-DG-BB VSUN700N-132BMH-DG Difference
Module efficiency 21.51 % 22.53 % 1.02 pp more efficient
Rated power 420 Wp 700 Wp 280 W more power
Power density 215.1 Wp/m² 225.3 Wp/m² 10.3 Wp/m² higher
Weight 24.7 kg 38.5 kg 13.8 kg lighter
Product warranty 25 yrs 12 yrs 13 yrs longer
Open-circuit voltage 38.11 V 48.50 V 10.39 V apart
Short-circuit current 14.07 A 18.32 A 4.25 A apart
Module area 1.953 m² 3.106 m² 1.154 m² apart
Weight per kWp 58.8 kg/kWp 55.0 kg/kWp 3.8 kg/kWp lighter
Voltage at max power 31.52 V 40.50 V 8.98 V apart
Current at max power 13.32 A 17.29 A 3.97 A apart
Cell count 108 132 24 cells apart
Dimensions 1722x1134x30 mm 2384x1303x35 mm 1722x1134x30 mm vs 2384x1303x35 mm
02

What it means on a roof

Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
Same temp coeff. for both panels (-0.300 %/°C), so a warmer roof scales both curves by the same factor: the totals fall together and neither panel gains on the other.
VSUN420N-108BMH-DG-BB
14,092 kWh
VSUN700N-132BMH-DG
23,486 kWh
Lifetime gap
9,394 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario VSUN420N-108BMH-DG-BB VSUN700N-132BMH-DG
Standard test conditions 25 °C 100.0% of rated power 420 W 700 W
Cool, bright day 40 °C 95.5% of rated power 401 W 669 W
Typical summer roof 55 °C 91.0% of rated power 382 W 637 W
Hot roof 70 °C 86.5% of rated power 363 W 606 W
03

Full specification

Parameter VSUN420N-108BMH-DG-BB VSUN700N-132BMH-DG Difference
Power and efficiency
Rated power 420 Wp 700 Wp +280 W for VSUN700N-132BMH-DG
Module efficiency 21.51 % 22.53 % +1.02 pp for VSUN700N-132BMH-DG
Power density 215.1 Wp/m² 225.3 Wp/m² +10.3 Wp/m² for VSUN700N-132BMH-DG
Open-circuit voltage 38.11 V 48.50 V 10.39 V apart
Voltage at max power 31.52 V 40.50 V 8.98 V apart
Short-circuit current 14.07 A 18.32 A 4.25 A apart
Current at max power 13.32 A 17.29 A 3.97 A apart
Temperature
Temperature coefficient -0.300 %/°C -0.300 %/°C Same
Mechanical
Dimensions 1722x1134x30 mm 2384x1303x35 mm 1722x1134x30 mm vs 2384x1303x35 mm
Module area 1.953 m² 3.106 m² 1.154 m² apart
Weight 24.7 kg 38.5 kg -13.8 kg for VSUN420N-108BMH-DG-BB
Weight per kWp 58.8 kg/kWp 55.0 kg/kWp -3.8 kg/kWp for VSUN700N-132BMH-DG
Warranty and degradation
Product warranty 25 yrs 12 yrs +13 yrs for VSUN420N-108BMH-DG-BB
Performance warranty 30 yrs 30 yrs Same
Annual degradation 0.40 %/yr 0.40 %/yr Same
Technology
Cell technology TOPCon TOPCon Same
Cell type Monocrystalline Monocrystalline Same
Cell count 108 132 24 cells apart
Bifacial Yes Yes Same
04

Against the whole database

14,129 panels
Efficiency
#7,958 vs #4,041
VSUN700N-132BMH-DG leads by 3,917 places
Power density
#7,946 vs #4,048
VSUN700N-132BMH-DG leads by 3,898 places
Heat behaviour
#6,152 vs #6,152
Tied - the same position in the database
Weight
#11,997 vs #9,445
VSUN700N-132BMH-DG leads by 2,552 places
Warranty
#21 vs #21
Tied - the same position in the database
Overall
#8,723 vs #1,212
VSUN700N-132BMH-DG leads by 7,511 places
05

More useful comparisons

Open the full database
Same series, other bin
VSUN
VSUN VSUN420N-108BMH-DG-BB vs VSUN VSUN430N-108BMH-DG-BB
3 differences, the largest is module efficiency
Same series, other bin
VSUN
VSUN VSUN420N-108BMH-DG-BB vs VSUN VSUN425N-108BMH-DG-BB
One difference: module efficiency
Same series, other bin
VSUN
VSUN VSUN420N-108BMH-DG-BB vs VSUN VSUN415N-108BMH-DG-BB
One difference: module efficiency
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN715N-132BMHT-DG
3 differences, the largest is module efficiency
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN710N-132BMHT-DG
3 differences, the largest is module efficiency
Same series, other bin
VSUN
VSUN VSUN700N-132BMH-DG vs VSUN VSUN705N-132BMHT-DG
The same specification on paper
06

Written summary

Checking cache...
07

Questions about this pairing

Which panel is better: VSUN VSUN420N-108BMH-DG-BB or VSUN VSUN700N-132BMH-DG?
According to our database: VSUN VSUN700N-132BMH-DG has higher module efficiency (22.53% vs 21.51%). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of VSUN VSUN420N-108BMH-DG-BB and VSUN VSUN700N-132BMH-DG?
VSUN VSUN420N-108BMH-DG-BB has a module efficiency of 21.51%, while VSUN VSUN700N-132BMH-DG is 22.53%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does VSUN VSUN420N-108BMH-DG-BB use vs VSUN VSUN700N-132BMH-DG?
VSUN VSUN420N-108BMH-DG-BB uses TOPCon cells; VSUN VSUN700N-132BMH-DG uses TOPCon. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on VSUN VSUN420N-108BMH-DG-BB and VSUN VSUN700N-132BMH-DG?
VSUN VSUN420N-108BMH-DG-BB has a 30 years power warranty; VSUN VSUN700N-132BMH-DG has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are VSUN VSUN420N-108BMH-DG-BB and VSUN VSUN700N-132BMH-DG bifacial panels?
Both VSUN VSUN420N-108BMH-DG-BB and VSUN VSUN700N-132BMH-DG are bifacial - they capture reflected light from the ground, which can add 5-15% more annual energy on ground-mount or elevated rooftop installations with a light surface beneath.

Shop prices: See 1 VSUN offer

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.