Silfab SIL-420-BG vs Silfab SIL-630 XL
VS
The verdict
630 XL leads on the differences that matter
The largest is temperature coefficient: 0.087 %/°C better in heat. 4 of 19 comparable parameters are identical.
See all 15 differencesHow alike are they
4
of 19 comparable
parameters are identical
parameters are identical
identical
differs
01
15 of 19 parameters
What actually differs
Parameter
420-BG
630 XL
Difference
Temperature coefficient
-0.377 %/°C
-0.290 %/°C
0.087 %/°C better in heat
Module efficiency
21.90 %
22.56 %
0.66 pp more efficient
Rated power
420 Wp
630 Wp
210 W more power
Weight
20.8 kg
29.5 kg
8.7 kg lighter
Power density
219.0 Wp/m²
225.6 Wp/m²
6.6 Wp/m² higher
Open-circuit voltage
46.36 V
57.49 V
11.13 V apart
Short-circuit current
11.40 A
13.66 A
2.26 A apart
Module area
1.918 m²
2.793 m²
0.875 m² apart
Cell technology
PERC
N-type
PERC vs N-type
Weight per kWp
49.5 kg/kWp
46.8 kg/kWp
2.7 kg/kWp lighter
Voltage at max power
38.51 V
48.47 V
9.96 V apart
Current at max power
10.91 A
13.00 A
2.09 A apart
Cell count
66
156
90 cells apart
Bifacial
No
Yes
No vs Yes
Dimensions
1864x1029x35 mm
2465x1133x35 mm
1864x1029x35 mm vs 2465x1133x35 mm
02
What it means on a roof
Thirty years of production
Each panel's own declared degradation curve, at 1,200 kWh/kWp a year
420-BG
14,160 kWh
630 XL
21,240 kWh
Lifetime gap
7,080 kWh
Output when it is hot
Rated power carried across the range a module actually sees
Scenario
420-BG
630 XL
Standard test conditions
25 °C
100.0% of rated power
420 W
630 W
Cool, bright day
40 °C
94.3% of rated power
396 W
603 W
Typical summer roof
55 °C
88.7% of rated power
372 W
575 W
Hot roof
70 °C
83.0% of rated power
349 W
548 W
03
Full specification
Parameter
420-BG
630 XL
Difference
Power and efficiency
Rated power
420 Wp
630 Wp
+210 W for 630 XL
Module efficiency
21.90 %
22.56 %
+0.66 pp for 630 XL
Power density
219.0 Wp/m²
225.6 Wp/m²
+6.6 Wp/m² for 630 XL
Open-circuit voltage
46.36 V
57.49 V
11.13 V apart
Voltage at max power
38.51 V
48.47 V
9.96 V apart
Short-circuit current
11.40 A
13.66 A
2.26 A apart
Current at max power
10.91 A
13.00 A
2.09 A apart
Temperature
Temperature coefficient
-0.377 %/°C
-0.290 %/°C
+0.087 %/°C for 630 XL
Mechanical
Dimensions
1864x1029x35 mm
2465x1133x35 mm
1864x1029x35 mm vs 2465x1133x35 mm
Module area
1.918 m²
2.793 m²
0.875 m² apart
Weight
20.8 kg
29.5 kg
-8.7 kg for 420-BG
Weight per kWp
49.5 kg/kWp
46.8 kg/kWp
-2.7 kg/kWp for 630 XL
Warranty and degradation
Product warranty
25 yrs
25 yrs
Same
Performance warranty
30 yrs
30 yrs
Same
Annual degradation
0.30 %/yr
0.30 %/yr
Same
Technology
Cell technology
PERC
N-type
PERC vs N-type
Cell type
Monocrystalline
Monocrystalline
Same
Cell count
66
156
90 cells apart
Bifacial
No
Yes
No vs Yes
04
14,129 panels
Against the whole database
Efficiency
#6,847
vs
#3,959
630 XL leads by 2,888 places
Power density
#6,850
vs
#3,927
630 XL leads by 2,923 places
Heat behaviour
#13,470
vs
#2,220
630 XL leads by 11,250 places
Weight
#3,065
vs
#1,365
630 XL leads by 1,700 places
Warranty
#21
vs
#21
Tied - the same position in the database
Overall
#8,049
vs
#1,047
630 XL leads by 7,002 places
05
Open the full database
More useful comparisons
Same series, other bin
Silfab
Silfab SIL-420-BG vs Silfab SIL-430 BG+
9 differences, the largest is module efficiency
Same series, other bin
Silfab
Silfab SIL-420-BG vs Silfab SIL-410-BG
3 differences, the largest is module efficiency
Same series, other bin
Silfab
Silfab SIL-420-BG vs Silfab SIL-380 BK
10 differences, the largest is rated power
Same series, other bin
Silfab
Silfab SIL-420-BG vs Silfab SIL-370 BK
10 differences, the largest is module efficiency
Same series, other bin
Silfab
Silfab SIL-630 XL vs Silfab SIL-640 XL
3 differences, the largest is module efficiency
Same series, other bin
Silfab
Silfab SIL-630 XL vs Silfab SIL-620 XL
3 differences, the largest is module efficiency
06
Written summary
Checking cache...
07
Questions about this pairing
Which panel is better: Silfab SIL-420-BG or Silfab SIL-630 XL?
According to our database: Silfab SIL-630 XL has higher module efficiency (22.56% vs 21.90%); Silfab SIL-630 XL tolerates heat better (temp coeff -0.290%/°C vs -0.377%/°C). See the full spec comparison and 30-year energy simulation above for a complete picture.
What is the efficiency of Silfab SIL-420-BG and Silfab SIL-630 XL?
Silfab SIL-420-BG has a module efficiency of 21.90%, while Silfab SIL-630 XL is 22.56%. Higher efficiency means more electricity from the same roof area - useful when space is limited.
What cell technology does Silfab SIL-420-BG use vs Silfab SIL-630 XL?
Silfab SIL-420-BG uses PERC cells; Silfab SIL-630 XL uses N-type. Modern n-type technologies (TOPCon, HJT, BC) typically deliver higher efficiency and lower degradation compared to older PERC (p-type) cells.
What is the warranty on Silfab SIL-420-BG and Silfab SIL-630 XL?
Silfab SIL-420-BG has a 30 years power warranty; Silfab SIL-630 XL has a 30 years power warranty. The power warranty guarantees a minimum percentage of rated output at the end of the warranty period (typically 80-87%). Product (materials) warranties are usually shorter.
Are Silfab SIL-420-BG and Silfab SIL-630 XL bifacial panels?
Silfab SIL-630 XL is bifacial (captures light from both faces); Silfab SIL-420-BG is monofacial. Bifacial panels work best on ground mounts or raised structures with a light-coloured surface underneath.
Shop prices: See 2 Silfab offers
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate. The thirty-year projection and the temperature scenarios are calculations from those figures, and each states its assumption above.